![PAC STORAGE PS 3000 Gen 1 Series Hardware Manual Download Page 78](http://html1.mh-extra.com/html/pac-storage/ps-3000-gen-1-series/ps-3000-gen-1-series_hardware-manual_745490078.webp)
78
Detecting a Failed PSU
If a PSU module fails, the system notifies you through the following indicators:
PSU status LED locations
Audible alarm (refer to Audible Alarms)
Firmware utility (refer to Firmware User Manual in the CD-ROM for details)
PAC Management S oftware (refer to the PAC Management Software User Manual in the
CD-ROM for details)
Replacing Power Supply Unit
A failed PSU should be replaced as soon as possible, but only when you have a
replacement module in your hand. Contact your vendor for more details (refer to Contact
Information).
WARNING
Although the system can operate with a failed PSU in a system, it is not
recommended to run the system with a failed PSU for an extended period of time. The
failed spare redundant PSU should be replaced as soon as possible!
To replace a PSU, follow these steps:
1.
Turn the switch to the off position and unplug the power cord.