65
Name
Color
Status
3. C_Dirty
Amber
Amber
indicates the following:
- Cache Memory is dirty.
- Data in flash backup module is being flushed to
cache.
- Errors occurred with cache memory (ECC errors).
- Data is being flushed from flash backup module to
drive (when power is restored).
- Super capacitor temperature reading is abnormal
(out of the 0 to 35°C range).
- Super capacitor is not present.
OFF
indicates that the cache is clean, and that the
Super capacitor is capable of sustaining memory in
case of power loss.
Blinking Amber
indicates cached data is being
transferred to the flash module after the occurrence
of a power outage. Once the transfer is done, all
LEDs will turn off.
This signal is local to each controller.
4. Hst Bsy
Green
Blinking Green
to indicate traffic on the host bus.
5. Restore
default
Green
Lights up Green
after pressing and holding Restore
Default Button to indicate a successful reset.
1G Ethernet Management Port LEDs
Name
Status
Description
1. Speed
ON
Indicates 1Gb connection is established.
Off
Indicates 10/100Mb connection is
established or no connection established.
2. Link / Active
ON
Indicates a connection has been
established.
FLASHING
Indicates data I/O.
OFF
Indicates connection is not established.