Content
Introduction - Description of operation - Important - Warranty....
Battery/Power monitor - Test program - Error Code......................
MCB functions................................................................................
Electronics terminals...................................................................
Hydro 1-3 Valve - Wiring diagram.................................................
Valves and Radio equipment........................................................
Hydro P/T - Wiring diagram..........................................................
Hydraulic valves - Service/Maintenance.......................................
Drawings..................................................................................
Trailer connectors.........................................................................
Control Unit and Produkt-Id.........................................................
6
www.p-light.com
established 2000
Introduction
Introduction
Thank you for choosing P-LIGHT from InnoNet AB. We hope that
P-LIGHT facilitates and streamlines your work and contributes to
a good working environment. Read the entire Instructions for use
before installing and putting P-LIGHT into service, this benefits
both you as a user and safeguards functionality.
Description of operation
P-LIGHT is designed for fully isolated lighting circuits, you connect
the trailer’s 2 lighting circuits. The circuits are isolated from each
other, but are controlled by push button 1 for ON and OFF. When
the parking/side lights are switched off (e.g. when the trailer is
disconnected), P-LIGHT is activated so that the connected parking
lights can be switched on and off easily with P-LIGHT. When the
trailer is reconnected to the vehicle and the vehicle lighting is
switched on, the ordinary parking/side lights on the trailer also
come on. At the same time, the specially developed controller
automatically starts to recharge the P-LIGHT batteries.
P-LIGHT also has an “AUX” output for e.g. radio control operation
or warning lights.
The P-LIGHT controller uses a small quiescent current (< 3mA)
which means that the batteries have to be fully charged before
the trailer taken out of service for any length of time. If it is to be
taken out of service for more than 1 month, the cable fuse at the
batteries must be removed.
Warranty and function!
- P-LIGHT provides a 1-year product warranty. In
the event of a warranty issue, InnoNet’s complaint
procedures must be followed.
- The warranty is only valid when original spare parts
and batteries are used.
- Service and maintenance are performed according to
the attached Service Manual.
Important to consider when installing P-LIGHT
- Use the correct cable dimensions.
- All connected equipment must be connected as
shown in the instructions.
- No equipment may be connected directly to the
batteries.
- Install P-LIGHT easily accessible for use, service and
maintenance and that the wiring from the truck to
P-LIGHT is as short as possible.
- In order to avoid galvanic corrosion, hot dip
galvanized bolt jointswhen mounting on a frame.
- Check the seal and tighten the M8 screws for the
cover by hand. Max 8-10 Nm to avoid damaging the
plastic washer and sealing strip.
- Check cable glands to make sure they are tightened
and sealed. Unused cable glands must be plugged.
For example, plug, bolt or the like.
- In the case of welding or any other type of work that
may damage electronics or batteries, these must
always be disconnected before work commences!
Documents and facts can be found on our support
website
support.p-light.com
. The site is updated
regularly.
Important!
IMPORTANT:
P-LIGHT® holds type approval to ECE No. 10. For this
to be valid, the incoming cable connected to terminals 3-7 must be
fitted through the installed ferrite core, as illustrated.
Mount ferrite core!
Page
6
7
7
8-9
18
19
20
21
22-26
27
28