8. General information
8.1 rating plate
The rating plate contains important information relating to the Wallbox. To see
this rating plate, the cover flap of the Wallbox must be removed as described
in "4.1 Overview and structure of the Wallbox Duo".
8.2 service notes
The Wallbox Duo is designed to require minimal maintenance. It can be
cleaned with common detergents as necessary. Please avoid the use of scrub-
bing powders or detergents with abrasive particles. Calibrated (MID) digital
meters are integrated into the P-CHARGE Wallbox Duo. These have a validity of
8 years and are approved for use by third parties for the calculation of electri-
cal energy. Once this time has elapsed, either a new meter is to be installed,
or the existing device must be audited by the calibration office / bureau of
standards. Please ensure that the device is calibrated regularly to ensure a cor-
rect metering procedure.
Repeated audit tests should be carried out on the P-CHARGE Wallbox Duo
in accordance with BGV A3 or the respective country standards and regula-
tions. The following audit test intervals apply in accordance with the following
extract from the BGB A3.
plant/facility/
equipment
audit test
intervals
type of function-
ality audit
inspector
Electrical plants and fixed
electrical installations in
"special installations or
locations" (DIN VDE 0100
Group 700)
1 year
for an orderly
condition
Qualified
electrical
technician
Residual current, differ-
ential current and earth
leakage circuit breaker
- in stationary plants
6 months
for error-free
functionality when
operating the test
facility
User
We recommend that a complete functionality audit of the P-CHARGE Wallbox
Duo be carried out every 6 months to ensure the best possible performance
of the device. Please note that these tasks should be carried out by trained,
technical personnel only.
8.3 trouble-shooting
In the event of an error, Button 3 resp. 6 is permanently backlit in red until the
error is corrected.
•
poWer failure:
In the event of power failure, the Wallbox Duo auto-
matically shuts down. Once power is reestablished, the Wallbox Duo will
restart by restoring the status saved at the point of outage. The power
backup circuit board in the EWS Box must, however, now be recharged.
This can take approx. 2-3 minutes. The Wallbox is then fully functional.
The control elements of the Wallbox are backlit while the power backup
circuit board is charging.
Wallbox type
Item number
Protection class
Date of manufacture
Serial number
Weight
Input voltage / Frequency
Power input
Image: Example of the rating plate
Source: BGV A3 Accident prevention regulation – Table 1A