2.6 safety information
Danger
Danger of electric voltage
A voltage-free state must be established prior to the start of
work at electrical plants and at the P-CHARGE Wallbox Duo in
order to avoid accidents resulting from contact with live parts.
Please note the 5 safety rules in accordance with DIN VDE
0105-100:2009-10 6.2.
Warning
circuitry and human protection facilities
The safety device integrated into the P-CHARGE Wallbox Duo
serves to protect the unit and is designed for use with this de-
vice only. The required circuitry and human protection facilities
are to be sufficiently dimensioned and provided by the installer.
Warning
Danger of suffocation/asphyxiation
Charging gassing batteries in an interior space can lead to
asphyxiation. According to the IEC 61851-1 the customer-
installed exhaust ventilation system must be controllable
via the Wallbox Duo. Monitoring of the customer-installed,
mandatory exhaust ventilation system cannot be performed
by the P-CHARGE Wallbox Duo and its integrated P-CHARGE
EWS Box.
caution
revocation of manufacturer's warranty due to impermiss-
ible changes to the device
Changes to the devices are not permitted. Non-conformance to
this regulation will result in revocation of manufacturer's warranty.
caution
Damage to the communication module
Installation and maintenance operations in direct conjunction
with the P-CHARGE EWS Box must always be carried out using
ESD equipment. Electrical discharging can damage internal
module components.