background image

18

TIMER

 

You can set the timer on/off. 
Timing start up: after setting timing start up, the machine will automatically start 

up and run when the timing time arrives.

In standby mode, press the timing key, and the corresponding timing indicator 

time value flashes.The timing time can be adjusted by adjusting the temperature 
up and down key (step distance is 1 hour), and the time interval range can be set 
as 1~24 hours.Finally, press this button to start timing. At this time, the timing 
indicates that the time value is always on, and the display displays the remaining 
time.

1. The machine will automatically start up and run after the timing time is set.
2. If you want to cancel the timing function, you can press this button again.
3. If the set timing boot time is not reached, press the "on/off" button in 

advance, the timing will be cancelled, and the machine will start up and run at the 
same time.

Regular shutdown: after regular shutdown is set, the machine will automatically 

stop running when the regular time is reached.

1. In the boot state, press the timing button, and the corresponding timing 

indicator time value flashes.The timing time can be adjusted by adjusting the 
temperature up and down key (step distance is 1 hour), and the time interval 
range can be set as 1~24 hours.Finally, press this button to start timing, and the 
timing LED will always be on;The digital tube displays the current set temperature.

2. The machine will shut down automatically when the timing time is set.
3. If you want to cancel the timing function, you can press this button again.
4. If the set timing shutdown time is not reached, press the "on/off" button in 

advance, the timing will be cancelled, and the machine will be shut down and stop 
running.

ON/OFF  

  

Press "on/off" to start up, and then press "on/off" to shut down.

WIND

Press the swing wind button to start the swing wind function;Press the swing 

button again, and the left and right swing function will be cancelled.

19

TEMP-

Under cooling and heating function, set in the range of 16 ~ 31 °C tempera-

ture.Every click on the temperature, set temperature reduced by 1 °C.

TEMP+

 

Under cooling and heating function, set in the range of 16 ~ 31 °C tempera-

ture.Each press keys on temperature, set temperature increase 1 °C.

MODE

    

Press the mode key to perform mode conversion and select one of the opera-

tion modes of "refrigeration, dehumidification, air supply, heating (optional), and 
automation".

Cooling operation

1. Press the mode key until the refrigeration indicator is on, and select the 
refrigeration function.While the refrigeration function is in progress, extend the 
bar Put the tube out of the window so that hot air can escape from the room.
2. According to the temperature rise or lower key can adjust the set temperature, 
the temperature range of 16-31 °C / 61 ~ 88 °F.
3. Press the wind speed button to select one of the high, medium and low wind 
speeds.

Note:

 In order to improve the cooling capacity of the machine, please note the 

following: A) if the room is in direct sunlight, please close the curtains. 
                B) do not place the machine where there is a heat source. 

Dehumidifying operation

1. Close the doors and Windows when using the machine to prevent excess 
moisture from entering the room.
2. Press the mode key, the dehumidification indicator will light up, and the 
display screen will display dH, and select the dehumidification function.In this 
mode, the wind speed is not adjustable, the default low speed.
3. In the case of selecting dehumidification mode, expansion tube is not 
required.

Fan operation

Press the mode key, the display will display FA, and select the function of air 

supply.Press the wind speed button to select one of the high, medium and low 

Summary of Contents for PA010996

Page 1: ...let Room temperature is higher than the setting temperature Electric heating mode Room temperature is lower than the setting temperature Cooling mode The doors or windows are not closed There are heat...

Page 2: ...f the refrigerant circuit If the appliance is installed operated or stored in a nonventilated area the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of...

Page 3: ...y cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 12 This appliance can be used by children aged from 8 years and ab...

Page 4: ...e avoid ed The area around the workspace shall be sectioned off Ensure that the conditions within the area have been made safe by control of flammable material 1 4 Checking for presence of refrigerant...

Page 5: ...stem that there is continuity of earth bonding 2 REPAIRS TO SEALED COMPONENTS 2 1 During repairs to sealed components all electrical supplies shall be discon nected from the equipment being worked upo...

Page 6: ...igerant charge shall be recovered into the correct recovery cylin ders The system shall be flushed with OFN to render the unit safe This process may need to be repeated several times Compressed air or...

Page 7: ...harge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylin ders shall be co...

Page 8: ...safety equipment before putting into service b Maintenance Portable equipment shall be repaired outside or in a workshop specially 12 equipped for servicing units with flammable refrigerants Ensure su...

Page 9: ...cause any spark Remove the refrigerant If the recovery is not required by national regulations drain the refrigerant to the outside Take care that the drained refrigerant will not cause any danger In...

Page 10: ...dehumidification and sleep mode the wind speed cannot be adjust ed The wind speed will be locked in low wind SLEEP 1 When in cooling mode when press the sleep button to enter sleep mode an hour later...

Page 11: ...ress on off to start up and then press on off to shut down WIND Press the swing wind button to start the swing wind function Press the swing button again and the left and right swing function will be...

Page 12: ...ctions of all machines can be realized through WIFI mobile APP Note optional function is to supply consumers according to the need to choose the specification shows the full functionality Temperature...

Page 13: ...ric safety require ments When using functions on cooling and dehumidifying keep an interval of at least 3 minutes between each POWER Power supply meets the requirements The socket is for AC use Do not...

Page 14: ...8 Fig 9 25 Maintenance Explanations Declaration 1 Before cleaning be sure to disconnect the unit from any electric supply outlet 2 Do not use gasoline or other chemicals to clean the unit 3 Do not was...

Reviews: