background image

2

1. The appliance is for indoor use only. 
2. Do not use the unit on a socket under repairs or not installed properly.
3. Do not use the unit, follow these precautions: 

A: Near to source of fire. 
B: An area where oil is likely to splash.
C: An area exposed to direct sunlight.  
D: An area where water is likely to splash. 
E: Near a bath, a laundry, a shower or a swimming pool. 

4. Never insert your fingers, rods into the air outlet. Take special care to warn 
children of these dangers.
5. Keep the unit upward while transport and storage, for the compressor locates 
properly. 
6. Before cleaning the air-conditioner, always turn off or disconnect the power 
supply. 
7. When moving the air-conditioner, always turn off and disconnect the power 
supply, and move it slowly. 
8. To avoid the possibility of fire disaster, the air-conditioner shall not be 
covered. 
9. All the air-conditioner sockets must comply with the local electric safety 
requirements. If necessary, please check it for the requirements.
10. Children should be supervised to ensure that they do not play with the 
appliance.

• The appliance must be stored in such a way as to prevent mechanical failure.
• Individuals who operate or work on the refrigerant circuit must have the 
appropriate certification issued by an accredited organization that ensures 
competence in handling refrigerants according to a specific evaluation recog-
nized by associations in the industry.
• Repairs must be performed based on the recommendation from the manufac-
turing company. Maintenance and repairs that require the assistance of other 
qualified personnel must be performed under the supervision of an individual 
specified in the use of flammable refrigerants.

3

11. If the supply cord is damaged, it must be replaced by the manufacturer, its 
service agent or similarly qualified persons in order to avoid a hazard.
12. This appliance can be used by children aged from 8 years and above and 
persons with reduced physical, sensory or mental capabilities or lack of experi-
ence and knowledge if they have been given supervision or instruction 
concerning use of the appliance in a safe way and understand the hazards 
involved. Children shall not play with the appliance. Cleaning and user mainte-
nance shall not be made by children without supervision.
13. The appliance shall be installed in accordance with national wiring regula-
tions.
14. Details of type and rating of fuses

T, 250V AC,2A.

15. Recycling

    This marking indicates that this product should not be disposed with other 
household wastes throughout the EU. To prevent possible harm to the environ-
ment or human health from uncontrolled waste disposal, recycle it responsibly 
to promote the sustainable reuse of material resources. To return your used 
device, please use the return and collection systems or contact the retailer 
where the product was purchased. They can take this product for environmen-
tal safe recycling.
16. GWP: R290: 3
17. Contact authorized service technician for repair or maintenance of this unit.
18. Do not pull , deform . or modify the power supply cord , or immerse it in 
water . Pulling or misuse of the power supply cord can result in damage to the 
unit and cause electrical shock.
19. Compliance with national gas regulations shall be observed.
20. Keep ventilation openings clear of obstruction.
21. Any person who is involved with working on or breaking into a refrigerant 
circuit should hold a current valid certificate from an industry-accredited 
assessment authority, which authorizes their competence to handle refrigerants 
safely in accordance with an industry recognized assessment specification.

Summary of Contents for PA010996

Page 1: ...let Room temperature is higher than the setting temperature Electric heating mode Room temperature is lower than the setting temperature Cooling mode The doors or windows are not closed There are heat...

Page 2: ...f the refrigerant circuit If the appliance is installed operated or stored in a nonventilated area the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of...

Page 3: ...y cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 12 This appliance can be used by children aged from 8 years and ab...

Page 4: ...e avoid ed The area around the workspace shall be sectioned off Ensure that the conditions within the area have been made safe by control of flammable material 1 4 Checking for presence of refrigerant...

Page 5: ...stem that there is continuity of earth bonding 2 REPAIRS TO SEALED COMPONENTS 2 1 During repairs to sealed components all electrical supplies shall be discon nected from the equipment being worked upo...

Page 6: ...igerant charge shall be recovered into the correct recovery cylin ders The system shall be flushed with OFN to render the unit safe This process may need to be repeated several times Compressed air or...

Page 7: ...harge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylin ders shall be co...

Page 8: ...safety equipment before putting into service b Maintenance Portable equipment shall be repaired outside or in a workshop specially 12 equipped for servicing units with flammable refrigerants Ensure su...

Page 9: ...cause any spark Remove the refrigerant If the recovery is not required by national regulations drain the refrigerant to the outside Take care that the drained refrigerant will not cause any danger In...

Page 10: ...dehumidification and sleep mode the wind speed cannot be adjust ed The wind speed will be locked in low wind SLEEP 1 When in cooling mode when press the sleep button to enter sleep mode an hour later...

Page 11: ...ress on off to start up and then press on off to shut down WIND Press the swing wind button to start the swing wind function Press the swing button again and the left and right swing function will be...

Page 12: ...ctions of all machines can be realized through WIFI mobile APP Note optional function is to supply consumers according to the need to choose the specification shows the full functionality Temperature...

Page 13: ...ric safety require ments When using functions on cooling and dehumidifying keep an interval of at least 3 minutes between each POWER Power supply meets the requirements The socket is for AC use Do not...

Page 14: ...8 Fig 9 25 Maintenance Explanations Declaration 1 Before cleaning be sure to disconnect the unit from any electric supply outlet 2 Do not use gasoline or other chemicals to clean the unit 3 Do not was...

Reviews: