VZR.248100.000 IG
K-14 Swing gate
Installation Guidelines
16
LEFT and RIGHT inputs can operate both in potential and pulse mode (is
triggered at grounding to GND terminal). Pulse mode is set by default.
Jumper (J1) should be installed to switch to potential operation mode. In
this case, left/right pass mode is activated only for period of action of control
signal to LEFT/RIGHT inputs
The cross-board has two relay outputs for ACS which work as "dry contact"
- Pass Okl and Pass Ok2. NO and COMM are normally open connection, NC and
COMM - normally closed connection.
Triggering of one of the terminal groups indicates opening of gate in
corresponding direction and its return in initial, closed, state (PassOk1 - right
PassOk2
– left).
D1 and D2 LEDs indicate relay status PassOk1 - right and PassOk2 - left.
The cross-board has relay output for ACS which work as "dry contact
–
Status. NO and COMM is normally open connection, its contacts are closed when
the product enters AP mode, in this case D3 diode lights up.
Also, LEDs indicating grounding of corresponding input to GND terminal
are installed on the cross-board:
1)
D4 signals receipt of LEFT input signal;
2)
D5 signals receipt of RIGHT input signal;
3)
D6 signals receipt of STOP input signal;