5.1 Connection of power supply
IT IS PROHIBITED TO:
POWER SUPPLY UNITS SHOULD BE WITH OUTPUT CURRENT OF
NOT MORE THAN 5 A, PULSE POWER SUPPLY UNITS SHOULD BE WITH
CURRENT OF NOT MORE THAN 7 A.
POWER SHOULD BE SUPPLIED THROUGH CONNECTING CABLE WITH
CROSS-SECTION LESS THAN 1.5 MM
2
; WHEN THE SUPPLY CABLE
LENGTH IS MORE THAN 10 M, IT IS RECOMMENDED TO USE CABLE
WITH CROSS-SECTION OF 2.5 MM
2
.
ATTENTION:
IT IS NOT RECOMMENDED TO INSTALL POWER SUPPLY
UNIT AT A DISTANCE OF MORE THAN 25 M FROM THE PRODUCT.
The product is powered by voltage of 24V DC.
It should be taken into account that the voltage drop increases with the
length of the supplied cable (operating voltage range is given in Operation Manual
VZR.248100.000 OP).
Install the power supply unit in a place where there is free space for
operator access. Connect power supply unit cable to POWER group of terminals
on the cross-board.
Connect ( + ) and ( - ) terminals of power supply unit to terminals (24V) and
(GND), respectively. Make sure that the cable is securely connected. Install the
door and lock it.