VZR.248100.000 IG
K-14 Swing gate
Installation Guidelines
15
Table 3
– Assignment of ACS terminals
Terminal marking
Terminal assignment
LEFT, RIGHT
One-time passing left/ right
(lower priority)
STOP
Passing forbidden (Stop mode)
(Medium priority)
AP
Is not used
GND
Common
ACS input priorities are different:
1)
STOP input has medium priority. When this input terminal is grounded to GND terminal,
the product enters "Stop" mode and does not react to other influences except AP;
2)
LEFT and RIGHT have the same low priority and provide
single
one-way passing. If both
inputs are closed, the leaf is open in the direction defining by input which was closed first. In
case when passing did not occur, the product will automatically enter "Stop" mode after 10
seconds (in pulse control mode). In potential control mode, the gate will be open as long as
there is a signal at its input from the controller to allow passing.
ATTENTION:
IN CASE OF STOP INPUT CLOSING - COMMANDS FROM
THE REMOTE CONTROL ARE NOT ACCEPTED AS ACS HAS HIGHER
PRIORITY.
STOP input is a potential one, i.e. the product operates in proper mode as
long as the input is grounded to GND terminal, after the terminal opening
– the
product enters "Stop" mode regardless of what mode was before ACS operation.