background image

4. Web Management 

 
 
 
 
 

 

AirLive POE-FSH8PW User’s Manual 

 

25

 

 

„

  Auto-Negotiation: Enable and Disable. Being set as ‘Enable’, the Speed, Duplex mode, 

Pause, Backpressure, TX Capability and Address Learning are negotiated automatically. 
When you set it as ‘Disable’, you have to assign those items manually. 

„

  Speed: When the Auto-Negotiation column is set as Disable, users have to set the 

connection speed to the ports ticked. 

„

  Duplex: When the Auto-Negotiation column is set as Disable, users have to set the 

connection mode in Half/Full to the ports ticked. 

„

  Pause: Flow Control for connection at speed of 10/100Mbps in Full-duplex mode. 

„

  Backpressure: Flow Control for connection at speed of 10/100Mbps in Half-duplex 

mode. 

„

  TX/RX Capability: When the Auto-Negotiation column is set as Disable, users have to 

set this column as Enable or Disable. 

„

  Addr. Learning: When the Auto-Negotiation column is set as Disable, users have to set 

this column as Enable or Disable. 

„

  Select Port No.: Tick the check boxes beside the port numbers being set. 

„

  Click Update to have the configuration take effect. 

„

  Current Status: Displays current port status. 

Summary of Contents for Air Live POE-FSH8PW

Page 1: ...1 POE FSH8PW 8 port 24V Passive POE Web Smart Switch User s Manual...

Page 2: ...cal photocopying or recording without the written consent of OvisLink Corp OvisLink Corp has made the best effort to ensure the accuracy of the information in this user s guide However we are not liab...

Page 3: ...the separation between the equipment and receiver z Connect the equipment into an outlet on a circuit different from that to which the receiver is connected z Consult the dealer or an experienced rad...

Page 4: ...6 Cabling Requirements 11 2 7 Connecting to Power 12 2 8 Reset to Default 12 3 LED Indicators 14 3 1 Comprehensive LEDs 14 3 2 LED Table 14 4 Web Management 15 4 1 Setup your computer for Web manageme...

Page 5: ...menu 31 4 17 VLAN Setting 32 4 18 VLAN Mode VLAN Setting 32 4 19 VLAN Member VLAN Setting 33 4 20 Multi to 1 Setting VLAN Setting 35 4 21 Per Port Counter 36 4 22 Trunk Setting 36 4 23 QoS Setting 37...

Page 6: ...wer is turned off you must turn on the power through web management This switch does not work with 802 3af and 802 3at PoE devices please make sure your device s PoE port can accept 24V passive PoE po...

Page 7: ...can damage your network card and even the switch We highly recommend you to leave at last one port as non PoE port and use this port for up linking or configuring purpose 1 2 Guide to the Chapters Cha...

Page 8: ...his switch does not work with 802 3af and 802 3at PoE devices z Please make sure your device s PoE port can accept 24V passive PoE power 12V passive PoE kit will not work with this switch z The switch...

Page 9: ...es about 5 seconds to complete LED Table LED Status Description On Power is on Power Off Power is off On Port is for connection Off No connection LINK AC T Flashing Data is transmitting or receiving O...

Page 10: ...switch s web management Step 5 Enter admin for username airlive for password Step 6 Go to Port Management and then select PoE See Figure B Step 7 Turn on the port number where you connect the device...

Page 11: ...to unpack your package contents 1 Clear out an adequate space to unpack the package carton 2 Open the package carton and take out the contents carefully 3 Put back all the shipping materials such as p...

Page 12: ...er to the connected PoE device For devices that are not compatible with Passive PoE please turn off the PoE function via the Web UI then the PoE port will not offer the power to these devices This PoE...

Page 13: ...level surface in a well ventilated area that is free from excessive dust In any case the installation site chosen for your switch has to comply with the following requirements The surface where you w...

Page 14: ...can be mounted on a standard size 19 inch rack which can in turn be placed in a wiring closet with other equipments Before you can mount the switch on the rack first you must attach the mounting brack...

Page 15: ...be purchased separately 2 5 Desktop Installation The POE FSH8PW PoE Switch has four rubber pads attached on each corner of its underside These pads serve as cushioning against vibration and prevent t...

Page 16: ...the top of the switch Leave at least 10cm of space around the switch to allow proper heating dissipation 2 6 Cabling Requirements For 100BASE TX ports The 8 RJ 45 ports require Cat 5 twisted pair UTP...

Page 17: ...h twisted pair cable Maximum Distance 100 meters 2 7 Connecting to Power POE FSH8PW PoE Switch features a universal auto select power supply unit which allows a power connection to a wide range of inp...

Page 18: ...e reset button continuously for10 seconds and release the reset button Step 3 The switch will reboot for 5 seconds and the configuration of switch will back to the default setting Key in the user ID a...

Page 19: ...minutes to look over this chapter and get familiar with the front panel LED indicators of your Switch 3 1 Comprehensive LEDs 3 2 LED Table LED Status Description On Power is on Power Off Power is off...

Page 20: ...your must set your computer to the same subnet as the switch For two network devices to be on the same subnet they must have the following 2 criteria Their IP address must be on the same subnet For e...

Page 21: ...Figure 4 1 Manual IP setting Step 1 Double click on the network connection status icon on the task bar This should bring up a window showing the status of the current network connection If there is n...

Page 22: ...via the default IP address Note2 The POE FSH8PW has DHCP client ability This allows DHCP server or router to assign IP automatically However we do not recommend turning on the DHCP client because the...

Page 23: ...tion and enter the IP address Subnet Mask and Gateway information offered by your ISP If your ADSL connection is PPPoE or PPTP type you have to connect through a router for remote management Cable Mod...

Page 24: ...port address 192 168 0 254 The switch s IP is 192 168 0 200 Please follow the instruction below to setup the router and switch for remote access On the Switch On the IP setting set the gateway to Rou...

Page 25: ...dmin Password airlive You should see the following welcome screen after the process is completed Menu Bar On the left side of the screen is the Menu bar where you and click to configure management fun...

Page 26: ...uthentication Configuration System IP Configuration System Status Load Default Setting Firmware Update Reboot Device In the following sessions we will talk in detail about the management functions und...

Page 27: ...t Mask Assign the subnet mask to the IP address Gateway Assign the network gateway for industrial switch If you change the IP address of this switch and then press Update It will show update successfu...

Page 28: ...lt is executed the all settings will be restored to default setting 4 9 Firmware Update Administrator menu Before the firmware update procedure is executed you should enter the password twice and then...

Page 29: ...formed if you click the Port Management on Home Page including Port Configuration Port Mirroring Bandwidth Control Broadcast Storm Control POE Configuration In the following sessions we will talk in d...

Page 30: ...as Disable users have to set the connection mode in Half Full to the ports ticked Pause Flow Control for connection at speed of 10 100Mbps in Full duplex mode Backpressure Flow Control for connection...

Page 31: ...Disable means this function is disabled 2 RX means copy the incoming packets of the selected source port to the selected destination port 3 TX means copy the outgoing packets of the selected source p...

Page 32: ...ort Management menu This page allows the setting of the bandwidth for each port The TX rate and Rx rate can be filled with the number ranging from 1 to 255 This number should be multiplied by the sele...

Page 33: ...he port1 4 is set to 10 20 30 40 respectively and Speed base is set to low The real bandwidth comes from the formula of 32Kbps 10 32Kbps 20 32Kbps 30 and 32Kbps 40 respectively After the update button...

Page 34: ...40 respectively After the update button is executed the real bandwidth will show up in TX fields c Low bandwidth for Rx Example 3 The RX bandwidth number of the port 5 port 8 is set to 50 60 70 80 re...

Page 35: ...0Mbps link speed the bandwidth setting should be less than 196 if the bandwidth is set to high For 10Mbps link speed the bandwidth setting should be less than 20 if the bandwidth base is set to high S...

Page 36: ...ming from the un selected port the switch treats it as the normal traffic Threshold Type in the threshold in the range between 1 and 63 to limit the maximum byte counts which a port can send or receiv...

Page 37: ...he VLAN Setting on Home Page including VLAN Mode VLAN Member Multi to 2 Setting In the following sessions we will talk in detail about the management functions under the VLAN Setting menu 4 18 VLAN Mo...

Page 38: ...al packet received at the source port This is the default setting when starting VLAN configuration You should change to either Add or Remove Tag Remove tag means the 802 1Q tag of the outgoing packet...

Page 39: ...rts that are on the same VLAN group In this configuration mode you do not need to worry about defining VLAN groups and VLAN IDs VLAN Member in Tag Based Mode In Tag Based Mode you need to define and c...

Page 40: ...mber of every existing group Then click on add The new group with its setting will be displayed at the bottom of the screen With the PVID Setting you define to which VLAN group incoming traffic belong...

Page 41: ...y shows both the received packet count excluding the incorrect packet and the transmitted packet count Receive packet Drop packet This category shows the number of received valid packet and the number...

Page 42: ...ombination of Source MAC Address and Destination MAC Address to be the selection for Trunk Hash Algorithm Traffic pattern on the network should be considered carefully before applying it When a proper...

Page 43: ...ation In the following sessions we will talk in detail about the management functions under the QoS Setting menu 4 24 Priority Mode QoS Setting There are three priority modes available to specify the...

Page 44: ...ned UDP TCP port groups and many well known TCP UDP ports The user defined port number may be a range or a specific number depending on the mask The operating theory for all 4 CoS types can be illustr...

Page 45: ...he unauthorized user from accessing the switch Each port can correspond to up to 3 MAC addresses To activate the port binding function you should enter the correct MAC address select the port number a...

Page 46: ...ock some specific applications There are two kinds of protocol filter functions The forward function makes the switch forward the selected protocol and drop other protocols The deny function makes the...

Page 47: ...to backup recovery the switch configuration The user can save configuration file to a specified file If the user wants to recover the original configuration which is saved at the specified path just...

Page 48: ...y the protocol and become a useless packet To prevent these packets from wasting the bandwidth this switch provide an option for the administrator to enable the queue aging function VLAN Striding By s...

Page 49: ...E FSH8PW User s Manual 44 4 31 Logout The administrator has write access for all parameters governing the onboard agent User should therefore assign a new administrator password as soon as possible an...

Page 50: ...port AirLive Models AP60 N Power Air 3G G DUO AirMax2 AirMax5 Transmission Media 10BaseT Cat 3 4 5 UTP STP 100BaseTX Cat 5 UTP STP LED Indicators Port LED LINK ACT PoE ACT Status Status LED Power Powe...

Page 51: ...f Power over Ethernet Features Number of Ports 10 100BaseTX with RJ 45 Connectors 24 port with PoE 10 100 1000BaseT with RJ 45 Connectors 2 Combo SFP Open Slots 2 MAC Address 4K Buffer Memory 1 5Mb Tr...

Page 52: ...tions AirLive POE FSH8PW User s Manual 47 per Device Dimensions 445 220 45 mm L x W x H Weight 2 54 kg Operating Temperature 0 to 60 Storage Temperature 20 to 90 Humidity 10 to 90 RH non condensing Ce...

Page 53: ...00BASE TX connection Make sure that the maximum switch to hub switch cable distance does not exceed 100 meters for 10 100 BASE TX connection Verify that the cabling type used is correct Check the corr...

Page 54: ...old the reset button continuously for 5 seconds and release the reset button Step 3 The switch will reboot for 20 seconds and the configuration of switch will back to the default setting Key in the us...

Reviews: