2. Installation of the Switch
AirLive POE-FSH8PW User’s Manual
8
Note: Be sure that you recorded the setting of your device, else all the setting will be erased
when pressing the “Reset” button.
The Rear Panel
The 3-pronged power plug is placed at the rear panel of the switch right side shown as
below.
2.3 Installation Site Preparation
You can mount POE-FSH8PW Passive PoE Switch either on desktop or on a 19-inch rack.
If you plan to mount the switch on desktop, please choose a steady, level surface in a
well-ventilated area that is free from excessive dust. In any case, the installation site
chosen for your switch has to comply with the following requirements:
The surface where you want to mount the switch must be able to sustain at least 1.5kg.
Do not place heavy objects (more than 3kg) on top of the switch.
The location must preferably be free from excessive dust, away from heat vent, hot-air
exhaust and direct sunlight.
The switch should not be placed near large electric motors or other strong
electromagnetic sources. As a reference, the strength of the electromagnetic field on
site should not exceed the (RFC) standards for IEC 801-3, Level 2(3V/M) field strength.