D-160TS-7-E
53
24.
PRODUCT CODE EXPLANATION
⑯
Regulations
0 Standard
No applicable law and regulations
G High Pressure Gas Safety Act
(Approved product)
※
w/Material test certificate
H High Pressure Gas Safety Act
(Individual test)
※
w/Material test certificate
(Designed on PO issued)
L Gas Business Act
(Approved product)
※
w/Material test certificate
(Designed on PO issued)
M Gas Business Act
※
w/Material test certificate
Q Electricity Business Act
(Certificate required)
※
w/Material test certificate
(Designed on PO issued)
R Electricity Business Act
※
w/Material test certificate
T Fire Service Act
※
w/Material test certificate
F w/Material test certificate
⑰ —
⑱
Converter (Power supply)
5 PA21 External power supply (24 to 32VDC)
9 Special
⑲
Converter configuration
2 Separately mounted
⑳
Display
0 Digital indicator (% instantaneous flow indication)
Pulse
G Open drain pulse
Communication interface
N Always "N"
Version code
B Version code: B
—
Sensor configuration
1 External sensor
Sensor type
1 Standard (Nominal Size: 20 to 500mm)
2 Gas-purge (Nominal Size: 50 to 500mm) Max. operating pressure: 1MPa at max.
3 Gas-purge (For low temp. or high temp.) (Designed on PO issued)
4 Double sensor
(Designed on PO issued)
5 Double sensor w/Magnet filter
(Designed on PO issued)
9 Special
Accompanied cable length
0 10m (Standard)
9 Specific cable length (Max. 30m)
Special
0 Standard
Z When "Special" or "Designed on PO issued" is chosen
※
1: Flange face to fit with the gasket is RF.
Flange serration according to ASME standard complies with ASME B 16.5−2003.
※
2
:
Make sure to use the dedicated explosionproof cable gland supplied with the flowmeter.
●
Main code
⑧
−
⑥
⑤
④
③
②
①
⑯
⑮
⑭
−
⑫
⑪
⑩
⑨
−
㉒
㉑
⑳
−
㉓
㉕
⑲
⑱
Model
Temp. category
Nominal Size
Fluid category
Converter configuration
Version code
Sensor configuration
Sensor type
Accompanied cable length
Special
Communication interface
Pulse
Display
Converter (Power supply)
Major Parts Material
Explosion-proof
Process connection
Main code
Regulations
㉗
㉖
㉘
/ / / Additional code
① ② ③
Model
V F W OVAL VORTEX FLOWMETER Wafer type (Nominal Size: 20 to 150mm)
V F Y
OVAL VORTEX FLOWMETER Wafer type, spigot joint type
(Nominal Size: 25 to 150mm)
V F F OVAL VORTEX FLOWMETER Flanged type (Nominal Size: 200 to 500mm)
④ ⑤ ⑥
Nominal Size
0 2 0 20mm (3/4
″
)
0 2 5 25mm (1
″
)
0 3 2 32mm (1
・
1/4
″
)
0 4 0 40mm (1
・
1/2
″
)
(Designed on PO issued)
0 5 0 50mm (2
″
)
0 8 0 80mm (3
″
)
1 0 0 100mm (4
″
)
1 5 0 150mm (6
″
)
2 0 0 200mm (8
″
)
2 5 0 250mm (10
″
)
3 0 0 300mm (12
″
)
3 5 0 350mm (14
″
)
(Designed on PO issued)
4 0 0 400mm (16
″
)
4 5 0 450mm (18
″
)
(Designed on PO issued)
5 0 0 500mm (20
″
)
⑦ —
⑧
Fluid category
G Gas
⑨
Temp. category
0 Standard
Max. fluid temperature: 130
℃
⑩
Major Parts Material
D
SUS304 or SUS304 equivalent
Allowed lowest temp.: -20
℃
(Nominal Size: 20 to 500mm)
G
Carbon steel (STPG370/SFVC2A/SS400)
Allowed lowest temp.: 0
℃
(Nominal Size: 200 to 500mm)
Z Special
⑪ ⑫
Process connection
※
1
J 0 JIS10K FF
J 1 JIS10K RF
For wafer type FF is also available
J B JIS16K RF
For wafer type FF is also available
J 2 JIS20K RF
For wafer type FF is also available
J 3 JIS30K RF
For wafer type FF is also available
P 1 JPI150 RF
For wafer type FF is also available
P 3 JPI300 RF
For wafer type FF is also available
P 6 JPI600 RF
(Designed on PO issued)
A 1 ASME150 RF
For wafer type FF is also available
A 3 ASME300 RF
For wafer type FF is also available
A 6 ASME600 RF
(Designed on PO issued)
Z 9 Special
⑬ —
⑭ ⑮
Explosion-proof
0 0 Non-explosionproof
J 4 TIIS…sensor: T4 (transmitter: T6)
※
2