High pressure service models (CA010 and CA015)
Item
Description
Model
CA010 (high pressure service)
CA015 (high pressure service)
Flowrate
Guar. min. meas. rate (kg/h)
24
78
Min. setting rate (kg/h)
120
390
Max. service rate (kg/h)
840
2550
Max. allowable rate (kg/h)
1680
5100
Accuracy
Liquid
[
±
0.2%
±
Zero stability error] of reading
At flow rate exceeding max. service rate, [
±
0.3%
±
Zero stability error] of reading
Gas
[
±
0.5%
±
Zero stability error] of reading
Repeatability
Liquid
[
±
0.1%
±
1/2 Zero stability error] of reading
Gas
[
±
0.25%
±
1/2 Zero stability error] of reading
Zero stability (kg/h)
0.21
0.636
Density
(liquid)
Measuring rate
0.3 to 2.0g/mL
Factory calib. acc. (opt)
±
0.004g/mL
Analog output accuracy
0.1% of full scale for respective accuracy
CAUTION: 1. For applications of volume flow measurement subject to taxation or in
transactions, consult the factory.
2. In gas measurement, the maximum permissible flow velocity varies with the kind
of gas and certain gases may be unacceptable for measurement. In such a case,
consult the factory.
●
Standard (CA100 to CA250), Low temperature explosionproof service models (CA100 to CA250)
Item
Description
Model
CA100
CA150
CA15H
CA200
CA20H
CA250
Flowrate
Guar. min. meas. rate (kg/h)
3420
7000
14000
Min. setting rate (kg/h)
17100
35000
70000
Max. allowable rate (kg/h)
684000
1400000
2800000
Max. service rate (kg/h)
342000
700000
1400000
Accuracy
±
0.1% of reading
(
※
1)
[
±
0.1%
±
Zero stability error] of reading
(
※
3)
Repeatability
±
0.05% of reading
(
※
2)
[
±
0.05%
±
1/2 Zero stability error] of reading
Zero stability (kg/h)
17.1
35
70
Density
(liquid)
Measuring rate
0.3 to 2.0g/mL
Factory calib. acc. (opt)
±
0.0005g/mL
Analog output accuracy
0.1% of full scale for respective accuracy
CAUTION: For applications of volume flow measurement subject to taxation or in transactions,
consult the factory.
L--740--28--E
1
NOTE:
NOTE: The general performance is based on factory calibration accuracy.
※
1:
±
Zero stability error is applied for flow rates below 5% of the max. service rate. (within guaranteed
flow range)
※
2:
±
1/2 Zero stability error is applied for flow rates below 5% of the max. service rate. (within guaranteed
flow range)
※
3: If higher accuracy (
±
0.1% of reading) is required, consult OVAL.
※
: The general performance is based on factory calibration accuracy.