![Oval ALTI mass CA001 Instructions Manual Download Page 148](http://html.mh-extra.com/html/oval/alti-mass-ca001/alti-mass-ca001_instructions-manual_1662152148.webp)
L--740--28--E
1
14.2 Type S
14.2.1 Stainless steel tube type
●
Main code
① ②
Model
C S ALTI
mass
Type S
③ ④ ⑤
Meter size/Nominal Diameter
JIS flange
ASME•JPI flange
Ferrule
0 1 0
15mm
1/2″
15A
0 1 5
15mm
1/2″
15A
0 2 5
25mm
1″
38 (ISO), IDF 1.5S
0 4 0
40mm
1·
1/2″
51 (ISO), IDF 2S
0 5 0
50mm
2″
63.5 (ISO), IDF 2.5S
0 8 0
80mm
3″
※Consult with OVAL
⑥ —
⑦
Density range
1 Low density liquids (0.5 to 1.0g/mL)
2 Ordinary density liquid (0.7 to 1.3g/mL)
3 High density liquid (1.0 to1.5g/mL)
⑧
Temp. category ※1
1
Standard (130℃ and lower
)
⑨
Major parts material
S SUS316L
⑩ ⑪
Process connection
J 1 JIS10K
J 2 JIS20K
A 1 ASME150
P 1 JPI150
H S ISO Ferrule
Z 9 Special
⑫ —
⑬
Explosion-proof
0 Non-explosionproof
1
TIIS ※2
2 ATEX/IECEx
3
KOSHA/KTL ※2
4
CSA (C-US) ※2
5
EAC ※2
7
NEPSI ※2
⑭
Ex-proof temp. class
0 Non-explosionproof
3 T3
4 T4
⑮
Regulations
0 Standard
G High Pressure Gas Safety Act
※3
(Approved product)
※w/Material test certificate
H High Pressure Gas Safety Act
※3
(Individual test)
※w/Material test certificate
(Designed on PO issued)
J High Pressure Gas Safety Act
※3
(Completion inspection)
※w/Material test certificate
T
Fire Service Act
※w/Material test certificate
S
Ship Classification Society Pattern Approval
P
Ship Classification Society Pattern Ap w/Material test certificate
F
w/Material test certificate
⑯
—
⑰
Transmitter
1 ALTI
mass
⑱
Transmitter construction ※4
1 Integrally mounted
2 Separately mounted
⑲
Power source
1 20 to 30VDC
2 85 to 264VAC (Safety rated 100 to 240VAC 50/60Hz)
⑳
Pulse output type
0 When "2, 3" are chosen for "Communication interface
"
B Voltage pulse
G Open drain pulse (equivalent to open collector pulse) (standard)
Communication interface
1 HART communication (HART protocol version 7, Bell202)
2 FOUNDATION Fieldbus H1communication (ITK version6)
3
PROFIBUS PA communication (Profile version3.02)
4 Modbus communication (RS-485 Modbus protocol)
Version code
A Version code: A
—
Special shape designation
0 Standard
Z Special shape (including polishing)
※1: Explosionproof specifications are restricted based on temperature class.
※2: "2, 3" for "Communication interface
" are in preparation and is not available yet.
※3: CS080 is not conform to (the Japan) High Pressure Gas Act.
※4: If temperature of the fluid exceeds 80℃ for explosionproof types, only "Separately mounted" type is available for the transmitter construction.
In case of non-explosionproof, integral type can be used up to 130℃ by restricting the transmitter ambient temp. to 45℃ at max.
⑧
⑦
−
⑤
④
③
②
①
−
⑮
⑭
⑬
−
⑪
⑩
⑨
⑰
㉒
㉑
⑳
㉔
−
⑲
⑱
Model
Temp. category
Meter size/Nominal Diameter
Density range
Power source
Transmitter construction
Transmitter
Regulations
Version code
Special shape designation
Communication interface
Pulse
Ex-proof temp. class
Major parts material
Explosion-proof
Process connection
Main code
/ / / Additional code