L--740--28--E
●
CA006 to CA080
Item
Description
Model
CA006
CA010
CA015
CA025
CA040
CA050
CA080
Nominal flange size
10mm, 3/8"
(
※
1),
DN15
15mm, 1/2", DN15
25mm, 1",
DN25
40mm, 1
・
1/2",
DN40
50mm, 2",
DN50
80mm, 3",
DN80
Materials
Wetted parts
SUS316L, Alloy C, Alloy C
Housing
SUS304
Process connection
JIS 10, 20, 30, 40, 63K RF / ASME (JPI) 150, 300, 600 RF
DIN PN 10, 16, 25, 40 RF(
※
2), IDF ferrule (
※
3), screw-in
Acceptable fluids
Liquid and gas
Density range
0 to 2.0g/mL
Viscosity range
Max.10000mPa
・
s (
※
4)
Temperature range
Separately mounted:
-
200 to
+
200
℃
, Integrally mounted:
-
200 to
+
150
℃
(
※
5) (
※
6)
Tube withstands (at 20
°
C)
9.4MPa (
※
7)
Max. operating pressure
Varies according to process connection.
Sensor housing withstands
(MPa). (
※
8)
3.8
3.0
2.2
1.6
1.8
1.4
Flow direction
Forward / Reverse
Explosionproof
configuration
Refer to section 10.4
Dusttight, waterproof
configuration
IP66 / 67
●
CA100 to CA250
Item
Description
Model
CA100
CA150
CA15H
CA200
CA20H
CA250
Nominal flange size
100mm, 4",
DN100
150mm, 6", DN150
200mm, 8", DN200
250mm, 10",
DN250
Materials
Wetted parts
SUS316L
Housing
SUS304
Process connection
JIS 10, 20, 30, 40K RF / ASME (JPI) 150, 300, 600 RF/ DIN PN 10, 16, 25, 40 RF
Acceptable fluid
Liquid
Density range
0.3 to 2.0g/mL
Viscosity range
Max.10000mPa
・
s (
※
1)
Temperature range
Separately mounted:
-
200 to
+
200
℃
, Integrally mounted:
-
200 to
+
150
℃
(
※
2) (
※
3)
Tube withstands (at 20
°
C) (
※
4)
13.56MPa
10.6MPa
8.8MPa
Max. operating pressure
Varies according to process connection.
Flow direction
Forward / Reverse
Explosionproof
configuration
Refer to section 10.4
Dusttight, waterproof
configuration
IP66 / 67
NOTES
※
1: 1/2" for ASME and JPI flanges.
※
2: DIN franges are available only to meters of the wet part material, "SUS316L"and"Alloy C".
※
3: For application to foods, this product does not comply with CE marking.
※
4: If the viscosity is 10000mPa·s or more, contact OVAL.
※
5: Refer to section 10.4 for explosionproof specification.
Refer to section 10.5 for the ambient temperature.
※
6: In case of PED specification, the minimum temperature lower limit is
-
196
℃
.
※
7: Refer to section 3.1.5 for PED specification.
※
8: This pressure does not represent the rated test pressure of a pressure vessel, but 1/4 of the breakdown test
pressure at OVAL (distorted enclosures do not constitute a failure of the test), or the data obtained from the FEM
analysis, whichever is lower (or safer).
※
: For availability of high pressure gas safety regulation compliant and CE mark compliant products, consult the
factory.
NOTES
※
1: If the viscosity is 10000mPa·s or more, contact OVAL.
※
2: Refer to section 10.4 for explosionproof specification.
Refer to section 10.5 for the ambient temperature.
※
3: In case of PED specification, the minimum temperature lower limit is
-
196
℃
.
※
4: Refer to section 3.1.5 for PED specification.
※