Installation

3 

 

3 : 1.Location

The intended use of GTA series amplifiers is in a rack 

only. The AC mains wirings of the units must be connected 
to a terminal box provided with a properly breaker (refer 
to 

§3 : 4.AC  Mains  supply

 for more details). It is not allowed 

to connect the GTA series AC mains connection directly to 
the power distribution system. For North America market 
we recommend to use an approved UL/CSA cable (i.e. ST 
600Vac 105°C 5x13AWG).

In order to limit the risk of mechanical damages, the 

amplifiers must be fixed to the rack using both frontal and 
rear mounting brackets. We recommend to use eight M6 or 
12-24 UNC-2B screws for threaded holes or cage nuts.

Install this amplifier as far as possible from radio tuners 

and TV sets. An amplifier installed in close proximity of such 
equipment may experience noise or generic performance 
degradation. Placing and using the amplifier for long periods 
of time on heat generating sources will affect its performance. 
Avoid placing the amplifier on heat generating sources.

This device must be powered exclusively by 

 

earth connected mains sockets in electrical 

networks compliant to the IEC 364 or similar rules.

Since the main power switch on this unit does not provide 

a complete insulation of the equipment from the main power, 
you must disconnect the main power source to turn off all 
power.

3 : 2.Cooling

Install the amplifier in a well-ventilated location: the 

ventilation openings must not be impeded by any item such 
as newspapers, tablecloths, curtains, etc; keep a distance of 
at least 50 cm from the front and rear ventilation openings 
of the amplifier.

All Outline amplifiers implement a forced-air cooling 

system to maintain low and constant operating tempera-
tures. Drawn by the internal fans, air enters from the front 
panel and is forced over all components, exiting at the back 
of the amplifier.

The amplifier’s cooling system features “intelligent” 

variable-speed DC fans which are controlled by the heatsink 
temperature sensing circuits: the fans speed will increase 
only when the temperature detected by the sensors rises 
over carefully predetermined values. This ensures that fan 
noise and internal dust accumulation are kept to a strict 
minimum.

Should however the amplifier be subject to an extreme 

thermal load, the fan will force a very large volume of air 
through the heat sink. In the extremely rare event that the 
amplifier should dangerously overheat, sensing circuits 
shut down all channels until the amplifier cools down to a 
safe operating temperature. Normal operation is resumed 
automatically without the need for user intervention.

GTA series amplifiers can be stacked one on top of the 

other due to the efficient cooling system they are equipped 
with.

There is however a safety limit to be observed: in case a 

rack with closed back panels is used, leave one rack unit empty 
every four installed amplifiers to guarantee adequate air flow 
(see 

Panel G, p. 6

).

3 : 3.Cleaning

Always use a dry cloth for cleaning the chassis and the 

front panel. Air filter cleaning should be scheduled according 
to the dust levels in the amplifier’s operating environment.

Disconnect the AC mains source before 

attempting to clean any part of the amplifier

In order to clean the vent filters you need to remove the 

front cover: never attempt to open any other part of the unit.

By means of a metric hex key #6, unscrew the two screws 

located on the left and right sides of the front panel, (see 

FIG. 

1

) gently lift the cover and remove the filter. You may use 

compressed air to remove the dust from filters, or wash it 
with clean water: in the latter case ensure that the filter is 
dry before reassembly.

3 : 4.AC mains supply

GTA series amplifiers offer worldwide AC acceptance and 

direct connection to any regional power line configuration. 
The power supply is now suitable to single-phase, two-phase 
or three-phase operation from 90 V

AC 

up to 464 V

AC

 without 

need of manual selection: true three-phase load balancing 
is directly achievable by the unit without any complex load 
assignment in the power distribution system design.

AC mains connection is provided by means of the eu-

roblock Phoenix PC 5/5-STF1-7,62 flying plug (Phoenix prod-
uct ID 1777862). Proper assembly of the AC mains conductors 
to the flying plug must respect the power line configuration.

Take care to connect any and all the five contacts of the 

flying plug to the power cords according to the configuration 
showed in 

Panel K, L, M

 at 

p.  9

 and 

p.  10

. In order to 

guarantee the proper connection we recommend to use an 
approved UL/CSA cable (i.e. ST 600Vac 105°C 5x13AWG).

OUT1CH1-2O

U

T

2

C

H

3

-

4

N L3 L2 L1 3PH

1PH

N

L

T UR

N TO LO

CK

TU R

N  TO L

OCK

MAINS

1=GND 2=IN+ 3=IN

ANALOG IN

3-4

1-2

GRAND TOURING AMPLIFIERS | outline.it

POWERED BY

Made in Italy

GTA

-Quattro

Quattro

GTA

FIG. 1: 

Use a #6 hex key to remove the front cover.

OUTLINE S.R.L.

Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy

Tel.: +39 030.3581341
Fax +39 030.3580431
[email protected]

www.outline.it

14

Summary of Contents for GTA OTTO

Page 1: ...OUT4 CH7 8 OUT3 CH5 6 OUT2 CH3 4 OUT1 CH1 2 POWER OUTPUTS 1 NEG 1 POS 2 2 POS NEG CH 2 4 6 8 CH 1 3 5 7 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it Otto GTA OUT1CH1 2O U T 2 C...

Page 2: ...A Otto GTA 19 498 454 88 483 5 443 GTA Otto OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 2...

Page 3: ...B Quattro GTA 19 498 454 44 483 5 443 GTA Quattro OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 3...

Page 4: ...CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GND 2 IN 3 IN ANALOG IN 1 GND 2 IN 3 IN ANALOG IN GRAND TOURING AMPLIFIERS Made in Italy POWERED BY MAINS 3PH 1PH L1 L2 L3 N N L OUT4 CH7 8 OUT3 CH5 6 OU...

Page 5: ...li 3 4 8 Uscita speakON canali 1 2 9 Ingresso XLR canali 1 2 AES 10 Ethernet etherCON porta secondaria 11 Connettore Phoenix ON OFF remoto 12 Ethernet etherCON porta primaria 13 Ingresso XLR canale 8...

Page 6: ...Otto outline it Otto GTA OUT1CH1 2O U T 2 C H 3 4 N L3 L2 L1 3PH 1PH N L T U R N TO LOCK T U RN TO LOCK MAINS 1 GND 2 IN 3 IN ANALOG IN 3 4 1 2 GRAND TOURING AMPLIFIERS outline it POWERED BY Made in...

Page 7: ...stato e MUTE Canale 4 7 Interruttore di accensione principale LED di stato e MUTE ALL 8 LED di stato e MUTE Canale 5 9 LED di stato e MUTE Canale 6 10 LED di stato e MUTE Canale 7 11 LED di stato e M...

Page 8: ...ingle ended loads CHB CHA A B NL4 speakON connector 1 2 1 2 1 2 1 2 1 2 1 2 NL4 speakON connector CHA CHA CHB CHB Bridge tied load Two single ended loads CHB CHA NL4 speakON connector 1 2 1 2 1 2 1 2...

Page 9: ...K L L N PE L N PE L1 L2 L3 L3 L2 L1 N N PE PE OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 9...

Page 10: ...ded by Outline Dopo essere stato correttamente cablato inserire e serrare il connettore volante nel guscio fornito da Outline L1 L2 PE L1 L2 PE OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Bresc...

Page 11: ...s that when the end user wishes to discard this product it must be sent to separate collection facilities for recovery and recycling By separating this product from other household type waste the volu...

Page 12: ...rate normally or has been dropped WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONN...

Page 13: ...er supplies 2 2 Unpacking checking for shipping damage Your Outline product has been completely tested and inspected before leaving the factory Carefully inspect the shipping package before opening it...

Page 14: ...he amplifier should dangerously overheat sensing circuits shut down all channels until the amplifier cools down to a safe operating temperature Normal operation is resumed automatically without the ne...

Page 15: ...in order to guarantee the proper conduction gauge 3 5 Precautions regarding in stallation WARNING TO PREVENT FIRE OR ELECTRIC SHOCK X This device must be powered exclusively by earth con nected mains...

Page 16: ...unit in the Armon a Workspace push on the rightmost button Otherwise if you click on Un Blink from the contextual menu of the amplifier into the Armon a Workspace all the front LEDs of the amplifier w...

Page 17: ...up ported via two Neutrik etherCON ports located on the rightmost side of the GTA Otto and GTA Quattro rear panels Fast Ethernet IEEE 802 3u 100 Mbit s and Gigabit Ethernet IEEE 802 3ab 1 Gbit s netwo...

Page 18: ...your GTA series amplifier platform you must store the software update file into a USB key and follow these steps 1 Switch the amplifier on and wait for the completion of the boot sequence 2 Plug the...

Page 19: ...tform does not reveal a DHCP server in the network during the startup it sets itself in AUTO IP mode 8 2 Dante networking The Dante GTA series amplifier platforms support Dante redundant networking vi...

Page 20: ...onfiguration of the transducers layout and raises toward the input selection and the definition of the backup policy Shortly the main steps to follow are 1 Load the loudspeaker presets or manually con...

Page 21: ...personnel If your amplifier needs repair contact your Outline distributor or Outline headquarters in Italy Even though most product malfunctioning can be solved through Outline Technical Support or yo...

Page 22: ...na versamento di liquidi o ca duta di oggetti nell apparecchio esposizione a pioggia o umidit o se l apparecchio non funziona normalmente o caduto ATTENZIONE RISCHIO DI SCOSSE ELETTRICHE NON APRIRE AT...

Page 23: ...a nuovi alimentatori multi fase universali 2 2 Disimballaggio e control lo dei danni di spedizione I prodotti Outline sono stati completamenti testati ed ispezionati prima di lasciare la fabbrica Isp...

Page 24: ...i amplificatori della Serie GTA possono essere posizio nati uno sopra l altro grazie all efficente sistema di raffredda mento di cui sono equipaggiati Esiste tuttavia un limite di cui tenere conto nel...

Page 25: ...ai terminali dell interruttore di sezionamento al fine di garantire la cor retta sezione di conduzione 3 5 Precauzioni per la corretta installazione AVVERTIMENTO PREVENZIONE DEGLI INCENDI E DELLE SCOS...

Page 26: ...nde e il sistema attiva una nuova rete Wi Fi locale con SSID come il seguente Outline MODELNAME SERIAL es Outline GTA Otto 71520 3 Accedi al tuo dispositivo mobile e modifica la configu razione Wi Fi...

Page 27: ...rso due porte etherCON Neutrik collocate sul lato destro del pannello po steriore di GTA Otto e GTA Quattro Sono supportati i proto colli di rete Fast Ethernet IEEE 802 3u 100 Mbit s e Gigabit Etherne...

Page 28: ...e anello L unit risponde all Armon a callback Il pulsante centrale si illumina quando il sistema in standby o in caso di guasto dell alimentatore Colore dell anello pulsante CENTRALE Colore Stato Bian...

Page 29: ...avvio negozia i parametri di rete Se la piattaforma di amplificazione Serie GTA non rileva un server DHCP sulla rete durante l avvio si auto configura in modalit AUTO IP 8 2 Rete Dante GTA Otto e GTA...

Page 30: ...nando una priorit alle quattro differenti sorgenti d ingresso per canale analogico AES3 e due flussi Dante il sistema in grado di commutare automaticamente alla connessione d ingresso pi affidabile in...

Page 31: ...ontatta il distributore Outline o direttamente la sede Outline Anche se la maggior parte dei malfunzionamenti pu essere risolta dall utente interpellando l Assistenza Tecnica Outline occasionalmente l...

Page 32: ...WIRING CLASS3 WIRING CLASS3 WIRING CLASS3 WIRING CLASS3 WIRING CLASS3 WIRING CE Low Voltage 2002 96 EC 2003 108 EC WEEE 2000 OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 03...

Page 33: ...ine GTA Wi Fi Outline GTA Quattro GTA Otto Outline 2 2 Outline X 1x GTA X 1x PC 5 5 STF1 7 62 Phoenix X 1x X 1x 2 3 2 4 A GTA Otto B GTA Quattro C GTA Otto D GTA Quattro E GTA Otto GTA Quattro F G H I...

Page 34: ...UL CSA cable ST 600Vac 105 C 5x13AWG OUT1CH1 2O U T 2 C H 3 4 N L3 L2 L1 3PH 1PH N L T U R N TO LOCK T U RN TO LOCK MAINS 1 GND 2 IN 3 IN ANALOG IN 3 4 1 2 GRAND TOURING AMPLIFIERS outline it POWERED...

Page 35: ...C D 10 kA CENELEC 2004 IEC 60446 2 N L1 L2 L3 E 2 3 4 1 PC 5 5 STF1 7 62 K 9 GTA 3 4 2 2P E 5 5 STF1 7 62 M 10 3 4 3 P N E L 9 3 5 X IEC 364 X X X Phoenix PC 5 5 STF1 7 62 X Outline X X X X X X X X X...

Page 36: ...Otto GTA TURN TO LO CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GND 2 IN 3 IN ANALOG IN 1 GND 2 IN 3 IN ANALOG IN GRAND TOURING AMPLIFIERS Made in Italy POWERED BY H N L OUT4 CH7 8 OUT3 CH5 6 OUT2...

Page 37: ...34 35 36 37 38 39 40 17 18 19 20 21 22 23 24 41 42 43 44 45 46 47 48 UP Link Power L1 L2 L3 N PE TURN TO LO CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GND 2 IN 3 IN ANALOG IN 1 GND 2 IN 3 IN ANALO...

Page 38: ...1 2 POWER OUTPUTS 1 NEG 1 POS 2 2 POS NEG CH 2 4 6 8 CH 1 3 5 7 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it Otto GTA TURN TO LO CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GN...

Page 39: ...X ETH1 X ETH2 Dante ETH1 Gigabit Ethernet ETH2 Gigabit Ethernet Dante Dante Dante GTA Dante GTA Otto 71520 Dante switch X Gigabit Ethernet X Non blocking X Quality of Service QoS queues X Diffserv DS...

Page 40: ...Armon a Fast Ethernet Armon a Discover Remote entities Armon a Armon a Armon a Armon aPlus GTA 9 1 DSP Outline GTA X GTA AES3 Dante X GTA GTA X Mute X FIR IIR X X FIR IIR Mute 9 2 bottom up 1 2 3 3 Ar...

Page 41: ...ine it tech outline it https outline it download Documents Tech_Support MO27A_Defect_Report_OUTLINE xlsx X Defect Report form distributorname_GTAQuattro_ sn17345 xlsx RMA tech outline it X RMA X RMA O...

Page 42: ...OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 42...

Page 43: ...INS 3PH 1PH L1 L2 L3 N N L OUT4 CH7 8 OUT3 CH5 6 OUT2 CH3 4 OUT1 CH1 2 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it 3 Phase Delta 4 Wire Grounded at Midpoint pf Phase and Contig...

Page 44: ...T1 CH1 2 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it 3 Phase Wye 3 Wire Grounded Neutral Point 9 A N B C A B C A B C A C B L1 L2 N N L N L N A B A A L1 B L2 C L3 N N TURN TO LO...

Page 45: ...r with the pole L2 The parallel connection must be done at the breaker output and not at the connector level Symbol n c means not connected Single Phase 2 Wire Nongrounded Neutral 13 A B C A B C N L N...

Page 46: ...00 W Maximum output power per channel 2 5200 W Maximum output power 8 Bridged 6000 W Maximum output power 4 Bridged 10400 W Peak total output all channels driven 20000 W Maximum unclipped output volta...

Page 47: ...Delay up to 2 s on input section up to 100 ms per output for time alignment Equalizer Raised cosine custom FIR parametric IIR peaking hi lo shelving all pass band pass band stop hi lo pass Crossover L...

Page 48: ...ducts without prior notice as a routine result of this philosophy For this reason any current Outline product may differ is some aspect from its description but will always equal or exceed the origina...

Reviews: