background image

O 

 

Regulatory information

FCC COMPLIANCE NOTICE

This device complies with part 15 of the FCC rules. Operation 
is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) this device must ac-
cept any interference received, including interference that 
may cause undesired operation.

CAUTION: Changes or modifications not expressly approved 

by the party responsible for compliance could void the us-
er’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply 
with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a resi-
dential installation. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harm-
ful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined 
by turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following 
measures:

 

X

Reorient or relocate the receiving antenna.

 

X

Increase the separation between the equipment and 
receiver.

 

X

Connect the equipment into an outlet on a circuit differ-
ent from that to which the receiver is connected.

 

X

Consult the dealer or an experienced radio/TV technician for 
help.

WEEE DIRECTIVE 

If the time arises to throw away your product, please recycle all 
the components possible.

This symbol indicates that when the end-user 
wishes to discard this product, it must be sent 
to separate collection facilities for recovery and 
recycling. By separating this product from other 
household-type waste, the volume of waste sent 
to incinerators or land-fills will be reduced and 
natural resources will thus be conserved.

The Waste Electrical and Electronic Equipment Directive 
(WEEE Directive) aims to minimise the impact of electrical and 
electronic goods on the environment. Outline s.r.l. comply with 
the Directive 2012/19/EU of the European Parliament on waste 
electrical and electronic equipment (WEEE) in order to reduce 
the amount of WEEE that is being disposed of in land-fill site.

EC DECLARATION OF CONFORMITY

We declare that under our sole responsibility the products:
Model Names:  

GTA Otto, GTA Quattro

Intended use: Professional Audio Amplifier

Are in conformity with the provisions of the following EU 
Directives, including all amendments, and with national leg-
islation implementing these directives:

 

X

2014/35/EU Low Voltage Directive

 

X

2014/30/EU Electromagnetic Compatibility Directive

 

X

2011/65/EU RoHs Directive

 

X

2014/53/EU Radio Equipment Directive

The following harmonized standards are applied:

 

X

EN 55032:2012 

 

X

EN 55035:2017 

 

X

EN 55103-2:2009 /IS:2012 

 

X

EN 61000-3-3:2013 

 

X

EN 61000-3-2:2014 

 

X

EN 60065:2014 /AC:2016  

Flero,
February 2020

All of our products are marked with the WEEE symbol; this in-
dicates that this product must NOT be disposed of with other 
waste. Instead it is the user’s responsibility to dispose of their 
waste electrical and electronic equipment by handing it over to 
an approved reprocessor. For more information about where 
you can send your waste equipment for recycling, please con-
tact your local distributor.

OUTLINE S.R.L.

Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy

Tel.: +39 030.3581341
Fax +39 030.3580431
[email protected]

www.outline.it

11

Summary of Contents for GTA OTTO

Page 1: ...OUT4 CH7 8 OUT3 CH5 6 OUT2 CH3 4 OUT1 CH1 2 POWER OUTPUTS 1 NEG 1 POS 2 2 POS NEG CH 2 4 6 8 CH 1 3 5 7 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it Otto GTA OUT1CH1 2O U T 2 C...

Page 2: ...A Otto GTA 19 498 454 88 483 5 443 GTA Otto OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 2...

Page 3: ...B Quattro GTA 19 498 454 44 483 5 443 GTA Quattro OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 3...

Page 4: ...CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GND 2 IN 3 IN ANALOG IN 1 GND 2 IN 3 IN ANALOG IN GRAND TOURING AMPLIFIERS Made in Italy POWERED BY MAINS 3PH 1PH L1 L2 L3 N N L OUT4 CH7 8 OUT3 CH5 6 OU...

Page 5: ...li 3 4 8 Uscita speakON canali 1 2 9 Ingresso XLR canali 1 2 AES 10 Ethernet etherCON porta secondaria 11 Connettore Phoenix ON OFF remoto 12 Ethernet etherCON porta primaria 13 Ingresso XLR canale 8...

Page 6: ...Otto outline it Otto GTA OUT1CH1 2O U T 2 C H 3 4 N L3 L2 L1 3PH 1PH N L T U R N TO LOCK T U RN TO LOCK MAINS 1 GND 2 IN 3 IN ANALOG IN 3 4 1 2 GRAND TOURING AMPLIFIERS outline it POWERED BY Made in...

Page 7: ...stato e MUTE Canale 4 7 Interruttore di accensione principale LED di stato e MUTE ALL 8 LED di stato e MUTE Canale 5 9 LED di stato e MUTE Canale 6 10 LED di stato e MUTE Canale 7 11 LED di stato e M...

Page 8: ...ingle ended loads CHB CHA A B NL4 speakON connector 1 2 1 2 1 2 1 2 1 2 1 2 NL4 speakON connector CHA CHA CHB CHB Bridge tied load Two single ended loads CHB CHA NL4 speakON connector 1 2 1 2 1 2 1 2...

Page 9: ...K L L N PE L N PE L1 L2 L3 L3 L2 L1 N N PE PE OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 9...

Page 10: ...ded by Outline Dopo essere stato correttamente cablato inserire e serrare il connettore volante nel guscio fornito da Outline L1 L2 PE L1 L2 PE OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Bresc...

Page 11: ...s that when the end user wishes to discard this product it must be sent to separate collection facilities for recovery and recycling By separating this product from other household type waste the volu...

Page 12: ...rate normally or has been dropped WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONN...

Page 13: ...er supplies 2 2 Unpacking checking for shipping damage Your Outline product has been completely tested and inspected before leaving the factory Carefully inspect the shipping package before opening it...

Page 14: ...he amplifier should dangerously overheat sensing circuits shut down all channels until the amplifier cools down to a safe operating temperature Normal operation is resumed automatically without the ne...

Page 15: ...in order to guarantee the proper conduction gauge 3 5 Precautions regarding in stallation WARNING TO PREVENT FIRE OR ELECTRIC SHOCK X This device must be powered exclusively by earth con nected mains...

Page 16: ...unit in the Armon a Workspace push on the rightmost button Otherwise if you click on Un Blink from the contextual menu of the amplifier into the Armon a Workspace all the front LEDs of the amplifier w...

Page 17: ...up ported via two Neutrik etherCON ports located on the rightmost side of the GTA Otto and GTA Quattro rear panels Fast Ethernet IEEE 802 3u 100 Mbit s and Gigabit Ethernet IEEE 802 3ab 1 Gbit s netwo...

Page 18: ...your GTA series amplifier platform you must store the software update file into a USB key and follow these steps 1 Switch the amplifier on and wait for the completion of the boot sequence 2 Plug the...

Page 19: ...tform does not reveal a DHCP server in the network during the startup it sets itself in AUTO IP mode 8 2 Dante networking The Dante GTA series amplifier platforms support Dante redundant networking vi...

Page 20: ...onfiguration of the transducers layout and raises toward the input selection and the definition of the backup policy Shortly the main steps to follow are 1 Load the loudspeaker presets or manually con...

Page 21: ...personnel If your amplifier needs repair contact your Outline distributor or Outline headquarters in Italy Even though most product malfunctioning can be solved through Outline Technical Support or yo...

Page 22: ...na versamento di liquidi o ca duta di oggetti nell apparecchio esposizione a pioggia o umidit o se l apparecchio non funziona normalmente o caduto ATTENZIONE RISCHIO DI SCOSSE ELETTRICHE NON APRIRE AT...

Page 23: ...a nuovi alimentatori multi fase universali 2 2 Disimballaggio e control lo dei danni di spedizione I prodotti Outline sono stati completamenti testati ed ispezionati prima di lasciare la fabbrica Isp...

Page 24: ...i amplificatori della Serie GTA possono essere posizio nati uno sopra l altro grazie all efficente sistema di raffredda mento di cui sono equipaggiati Esiste tuttavia un limite di cui tenere conto nel...

Page 25: ...ai terminali dell interruttore di sezionamento al fine di garantire la cor retta sezione di conduzione 3 5 Precauzioni per la corretta installazione AVVERTIMENTO PREVENZIONE DEGLI INCENDI E DELLE SCOS...

Page 26: ...nde e il sistema attiva una nuova rete Wi Fi locale con SSID come il seguente Outline MODELNAME SERIAL es Outline GTA Otto 71520 3 Accedi al tuo dispositivo mobile e modifica la configu razione Wi Fi...

Page 27: ...rso due porte etherCON Neutrik collocate sul lato destro del pannello po steriore di GTA Otto e GTA Quattro Sono supportati i proto colli di rete Fast Ethernet IEEE 802 3u 100 Mbit s e Gigabit Etherne...

Page 28: ...e anello L unit risponde all Armon a callback Il pulsante centrale si illumina quando il sistema in standby o in caso di guasto dell alimentatore Colore dell anello pulsante CENTRALE Colore Stato Bian...

Page 29: ...avvio negozia i parametri di rete Se la piattaforma di amplificazione Serie GTA non rileva un server DHCP sulla rete durante l avvio si auto configura in modalit AUTO IP 8 2 Rete Dante GTA Otto e GTA...

Page 30: ...nando una priorit alle quattro differenti sorgenti d ingresso per canale analogico AES3 e due flussi Dante il sistema in grado di commutare automaticamente alla connessione d ingresso pi affidabile in...

Page 31: ...ontatta il distributore Outline o direttamente la sede Outline Anche se la maggior parte dei malfunzionamenti pu essere risolta dall utente interpellando l Assistenza Tecnica Outline occasionalmente l...

Page 32: ...WIRING CLASS3 WIRING CLASS3 WIRING CLASS3 WIRING CLASS3 WIRING CLASS3 WIRING CE Low Voltage 2002 96 EC 2003 108 EC WEEE 2000 OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 03...

Page 33: ...ine GTA Wi Fi Outline GTA Quattro GTA Otto Outline 2 2 Outline X 1x GTA X 1x PC 5 5 STF1 7 62 Phoenix X 1x X 1x 2 3 2 4 A GTA Otto B GTA Quattro C GTA Otto D GTA Quattro E GTA Otto GTA Quattro F G H I...

Page 34: ...UL CSA cable ST 600Vac 105 C 5x13AWG OUT1CH1 2O U T 2 C H 3 4 N L3 L2 L1 3PH 1PH N L T U R N TO LOCK T U RN TO LOCK MAINS 1 GND 2 IN 3 IN ANALOG IN 3 4 1 2 GRAND TOURING AMPLIFIERS outline it POWERED...

Page 35: ...C D 10 kA CENELEC 2004 IEC 60446 2 N L1 L2 L3 E 2 3 4 1 PC 5 5 STF1 7 62 K 9 GTA 3 4 2 2P E 5 5 STF1 7 62 M 10 3 4 3 P N E L 9 3 5 X IEC 364 X X X Phoenix PC 5 5 STF1 7 62 X Outline X X X X X X X X X...

Page 36: ...Otto GTA TURN TO LO CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GND 2 IN 3 IN ANALOG IN 1 GND 2 IN 3 IN ANALOG IN GRAND TOURING AMPLIFIERS Made in Italy POWERED BY H N L OUT4 CH7 8 OUT3 CH5 6 OUT2...

Page 37: ...34 35 36 37 38 39 40 17 18 19 20 21 22 23 24 41 42 43 44 45 46 47 48 UP Link Power L1 L2 L3 N PE TURN TO LO CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GND 2 IN 3 IN ANALOG IN 1 GND 2 IN 3 IN ANALO...

Page 38: ...1 2 POWER OUTPUTS 1 NEG 1 POS 2 2 POS NEG CH 2 4 6 8 CH 1 3 5 7 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it Otto GTA TURN TO LO CK TURN TO LOCK TUR N TO LOCK TURN TO LOC K 1 GN...

Page 39: ...X ETH1 X ETH2 Dante ETH1 Gigabit Ethernet ETH2 Gigabit Ethernet Dante Dante Dante GTA Dante GTA Otto 71520 Dante switch X Gigabit Ethernet X Non blocking X Quality of Service QoS queues X Diffserv DS...

Page 40: ...Armon a Fast Ethernet Armon a Discover Remote entities Armon a Armon a Armon a Armon aPlus GTA 9 1 DSP Outline GTA X GTA AES3 Dante X GTA GTA X Mute X FIR IIR X X FIR IIR Mute 9 2 bottom up 1 2 3 3 Ar...

Page 41: ...ine it tech outline it https outline it download Documents Tech_Support MO27A_Defect_Report_OUTLINE xlsx X Defect Report form distributorname_GTAQuattro_ sn17345 xlsx RMA tech outline it X RMA X RMA O...

Page 42: ...OUTLINE S R L Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 030 3581341 Fax 39 030 3580431 info outline it www outline it 42...

Page 43: ...INS 3PH 1PH L1 L2 L3 N N L OUT4 CH7 8 OUT3 CH5 6 OUT2 CH3 4 OUT1 CH1 2 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it 3 Phase Delta 4 Wire Grounded at Midpoint pf Phase and Contig...

Page 44: ...T1 CH1 2 1 2 3 4 5 6 7 8 7 8 5 6 AES3 IN 3 4 1 2 AES3 IN GTA Otto outline it 3 Phase Wye 3 Wire Grounded Neutral Point 9 A N B C A B C A B C A C B L1 L2 N N L N L N A B A A L1 B L2 C L3 N N TURN TO LO...

Page 45: ...r with the pole L2 The parallel connection must be done at the breaker output and not at the connector level Symbol n c means not connected Single Phase 2 Wire Nongrounded Neutral 13 A B C A B C N L N...

Page 46: ...00 W Maximum output power per channel 2 5200 W Maximum output power 8 Bridged 6000 W Maximum output power 4 Bridged 10400 W Peak total output all channels driven 20000 W Maximum unclipped output volta...

Page 47: ...Delay up to 2 s on input section up to 100 ms per output for time alignment Equalizer Raised cosine custom FIR parametric IIR peaking hi lo shelving all pass band pass band stop hi lo pass Crossover L...

Page 48: ...ducts without prior notice as a routine result of this philosophy For this reason any current Outline product may differ is some aspect from its description but will always equal or exceed the origina...

Reviews: