11. Apply silicone lubrication to the knife valve actuator rod(s).
12. Be sure ALL water from ALL plumbing fixtures has been drained.
13. Close holding tank drain valves.
14. Locate water pump, and close the winterization pick-up tube valve next to the water pump.
16. Remove threaded plug from the pick-up tube.
17. Place the pick-up tube in a container of approved non-toxic antifreeze below the trailer.
18. Turn water pump on (12-volt power must be on).Open valve on pick up line and
Pick-up tube should begin drawing antifreeze from the container.
19. Open each water faucet, run the water pump and let about a cup of antifreeze solution flow continuously through
each faucet. Close each water faucet.
20. Flush the toilet until the antifreeze solution flow continuously. Release flush mechanism.
21. Your trailer may be equipped with a water heater bypass. Winterize the hot water lines by opening each hot
hot water faucet, allowing antifreeze solution to flow continuously, and then close each faucet. This will
require considerably more antifreeze solution, and you may choose to do this step before winterizing the cold
water lines so you can recycle the solution.
22. Pour one cup of antifreeze solution down each drain.
23. Install protective caps:
Waste tank drain outlet cap
Winterization pick-up tube plug
24. If your refrigerator is equipped with an ice maker, winterize it as follows:
1. Shut off the water supply valve to the ice maker.
2. Place a shallow pan under the water solenoid valve.
3. Remove the inlet fitting to the ice maker water solenoid valve. Drain the water from the supply line.
4. Remove the plastic nut and water line from the outlet side of the water solenoid valve. Drain water from the line.
5. Cycle the ice maker several times while blowing compressed air through the water solenoid valve. Be sure
all water is out of the solenoid. NOTE: Your trailer dealer can do this for you.
6. Reconnect and tighten the lines on the solenoid valve. Leave the water supply turned off until temperatures
are above 32°F/0°C.
7. Dry out the ice maker mold assembly with a soft cloth. Place the bail arm to the UP/OFF position.
96
NOTE
When filling the plumbing systems with antifreeze, be sure to open and operate all fixtures and valves
allowing the antifreeze solution to flow freely.