20
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina-B Installation Manual • 4066-500 Rev. B • 5/14
D. Valve Access
The valve and controls are located in the control box
(Refer to Figure 6.1). Remove the screws and remove
the lid.
The control box is designed to be moved out to allow for
the thickness of the
fi
nish material or moved from the
appliance and repositioned.
• Loosen the two bolts found inside the box in the bottom
of the control box.
• Slide the box out as necessary.
• Tighten the screws.
• The control box can be removed from the appliance
and repositioned (up to approximately 4-1/2 ft. from
the appliance).
WARNING! Risk of Fire!
Risk of Explosion!
DO NOT
allow gas line to kink or bend while relocating control box.
Gas could leak.
• Make sure the lid will
fi
t over the box without interfering
with the
fi
nish material.
• The control box lid must be accessible and removable.
• Caulk around the perimeter of the box to prevent water
in
fi
ltration.
Note:
The control box lid can be painted as desired.
Use sandpaper or other abrasive material to scuff
the surface prior to painting.
E. High Altitude Installations
NOTICE:
If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Input ratings are certi
fi
ed without a
reduction of input rate for elevations up to 4500 feet
(1370 m)above sea level. Please consult provincial and/
or local authorities having jurisdiction for installations at
elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
ori
fi
ce size.