19
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina-B Installation Manual • 4066-500 Rev. B • 5/14
Figure 6.1 Control Box & Access Panel Locations
• The incoming gas line can be installed from the bottom
of the appliance structure, from the side or from the
rear.
• The incoming line should be connected to the 1/2 in.
connection on the manual shutoff valve provided with
the appliance.
• Cut cable ties holding manual shutoff valve and the
fl
ex line and pilot line prior to
fi
nishing to allow for easy
access.
WARNING! Rick of Fire or Explosion!
Gas build-up dur-
ing line purge could ignite.
• Purge should be performed by qualified service
technician.
• Ensure adequate ventilation.
• Ensure there are no ignition sources such as sparks or
open
fl
ames.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Check all
fi
ttings and connections with a non-corrosive
commercially available leak-check solution.
DO NOT
use
open
fl
ame. Fittings and connections could have loos-
ened during shipping and handling.
• Accessibility to the shutoff valve is required after
installation, or another accessible shutoff is required.
Figure 6.2 Connect Incoming Gas Line to Manual Shutoff Valve
• The
fl
ex line and gas shutoff valve can be accessed
after installation by removing four screws from the valve
mounting bracket at the rear of the control box.
CUT CABLE TIE
CUT CABLE TIE
INCOMING GAS LINE
INCOMING GAS LINE
The access panel is located below the control box. It
will be easier to make gas connection after the control
box is in its
fi
nal position. If necessary, relocate control
box prior to making gas connection. See Section 6.D.
• Remove the screws holding the access panel.
• Set the panel and screws aside for reinstallation.
CONTROL BOX
CONTROL
BOX
ACCESS PANEL
ACCESS PANEL