Specifications
48
900-0020-01-00 Rev A
Table 11
GS8048 Inverter Settings
Field Item
Default
Minimum
Maximum
Aux Control
Off
Off, Auto
or
On
Aux Mode
Vent Fan
Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,
DC Divert, IEEE, Source Status, AC Divert
(Load Shed)
ON: Batt >
56 Vdc
40 Vdc
72 Vdc
(Load Shed ON)
Delay
30 Secs
6 Secs
1500 Secs
(Load Shed)
OFF: Batt <
56 Vdc
48 Vdc
72 Vdc
(Load Shed OFF)
Delay
18 Secs
6 Secs
1500 Secs
(Gen Alert)
ON: Batt <
44 Vdc
40 Vdc
56 Vdc
(Gen Alert ON)
Delay
30 Secs
6 Secs
1500 Secs
(Gen Alert)
OFF: Batt >
56 Vdc
48 Vdc
72 Vdc
(Gen Alert OFF)
Delay
30 Secs
6 Secs
1500 Secs
(Vent Fan)
ON: Batt >
56 Vdc
48 Vdc
72 Vdc
(Vent Fan)
Off Delay
18 Secs
6 Secs
1500 Secs
(DC Divert)
ON: Batt >
56 Vdc
48 Vdc
72 Vdc
(DC Divert ON)
Delay
30 Secs
6 Secs
1500 Secs
(DC Divert)
OFF: Batt <
44 Vdc
40 Vdc
56 Vdc
(DC Divert OFF)
Delay
30 Secs
6 Secs
1500 Secs
(AC Divert)
ON: Batt >
56 Vdc
48 Vdc
72 Vdc
(AC Divert ON)
Delay
30 Secs
6 Secs
1500 Secs
(AC Divert)
OFF: Batt <
44 Vdc
40 vdc
56 Vdc
Auxiliary Output
(AC Divert OFF)
Delay
30 Secs
6 Secs
1500 Secs
Aux Control
Off
Off, Auto
or
On
Aux Mode
Gen Alert
Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,
DC Divert, IEEE, Source Status, AC Divert
(Load Shed)
ON: Batt >
56 Vdc
40 Vdc
72 Vdc
(Load Shed ON)
Delay
30 Secs
6 Secs
1500 Secs
(Load Shed)
OFF: Batt <
56 Vdc
48 Vdc
72 Vdc
(Load Shed OFF)
Delay
18 Secs
6 Secs
1500 Secs
(Gen Alert)
ON: Batt <
44 Vdc
40 Vdc
56 Vdc
(Gen Alert ON)
Delay
30 Secs
6 Secs
1500 Secs
(Gen Alert)
OFF: Batt >
56 Vdc
48 Vdc
72 Vdc
(Gen Alert OFF)
Delay
30 Secs
6 Secs
1500 Secs
(Vent Fan)
ON: Batt >
56 Vdc
48 Vdc
72 Vdc
(Vent Fan)
Off Delay
18 Secs
6 Secs
1500 Secs
(DC Divert)
ON: Batt >
56 Vdc
48 Vdc
72 Vdc
(DC Divert ON)
Delay
30 Secs
6 Secs
1500 Secs
(DC Divert)
OFF: Batt <
44 Vdc
40 Vdc
56 Vdc
(DC Divert OFF)
Delay
30 Secs
6 Secs
1500 Secs
(AC Divert)
ON: Batt >
56 Vdc
48 Vdc
72 Vdc
(AC Divert ON)
Delay
30 Secs
6 Secs
1500 Secs
(AC Divert)
OFF: Batt <
44 Vdc
40 vdc
56 Vdc
Auxiliary
Relay
(AC Divert OFF)
Delay
30 Secs
6 Secs
1500 Secs
Inverter Stacking
Stack Mode
Master
Master, Slave
Master Power Save Level
0 0 31
Power Save
(in Stacking Menu)
Slave Power Save Level
1 1 31
Grid-Tie Enable
Y
Y
or
N
Sell Voltage
52 Vdc
40 Vdc
60 Vdc
Grid-Tie Sell
Grid-Tie Window
IEEE
IEEE
or
user
Input Voltage
0 -7 7
Output Voltage
0 -7 7
Calibrate
Battery Voltage
0 -0.8 0.8
Summary of Contents for Radian GS8048
Page 1: ...Radian Series Inverter Charger GS8048 Operator s Manual...
Page 40: ...Troubleshooting 38 900 0020 01 00 Rev A NOTES...
Page 46: ...Troubleshooting 44 900 0020 01 00 Rev A NOTES...
Page 56: ...Warranty 54 900 0020 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK...
Page 59: ...900 0020 01 00 Rev A 57 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 60: ...North America 5917 195th St NE 7 Arlington WA 98223 USA 1 360 435 6030 900 0020 01 00 Rev A...