background image

VERSION: 5X2-2016-07-15 

eMH1

WALLBOX 

with socket

Instruction Manual

MADE IN

GERMANY

Albert-Büttner-Straße 11
D-91207  Lauf / Pegnitz

Tel.  +49 (0) 9123 188-0
Fax    +49 (0) 9123  188-188

[email protected]
www.abl.de

ABL SURSUM
Bayerische  Elektrozubehör  GmbH & Co. KG

Summary of Contents for eMH1 WALLBOX

Page 1: ...VERSION 5X2 2016 07 15 eMH1 WALLBOX with socket Instruction Manual...

Page 2: ...sum Bayerische Elektrozubeh r GmbH Co KG Albert B ttner Stra e 11 91207 Lauf Pegnitz Germany Phone 49 0 9123 188 0 Fax 49 0 9123 188 188 Web www abl de Email info abl de Support Phone 49 0 9123 188 60...

Page 3: ...npacking 7 Available accessories 7 Installation and power supply connection 9 Prerequisites for the mounting site and installation 9 Preparation and mechanical installation 10 Electrical installation...

Page 4: ...e integrated RCCB only for model variants with RCCB 20 Taking the device out of operation 20 Appendix 22 Specifications 22 Trademarks 24 CE certification and compliance declaration 25 Glossary Definit...

Page 5: ...CIRCUMSTANCES CAUTION Sections marked with this symbol draw attention to further hazards that may lead to damage to the station itself or to other electric devices Actions marked with this symbol mus...

Page 6: ...red by authorized or qualified specialist personnel In case you require service see next page always turn first to the dealer who supplied the device to you Service is required when e g the housing th...

Page 7: ...t NOT UNDER ANY CIRCUMSTANCES make any changes to the housing or the internal wiring of the device Any disregard of this instruction fundamentally breaches the guarantee provisions and voids the warra...

Page 8: ...the device out of operation immediately In this case please turn to an authorized service partner or the dealer from whom you purchased the product You must NOT UNDER ANY CIRCUMSTANCES attempt to res...

Page 9: ...ng connectors of the eMH1 are designed for the shortest possible charging times We place the highest value on user safety in all our products Your eMH1 wall box therefore features an integrated residu...

Page 10: ...rated RCCB Type A integrated DC fault current detector charging output 11 kW EVSE 512 230 V 50 Hz 32 A Single phase EVSE 502 model variant without integrated DC fault current detector charging output...

Page 11: ...re components be missing after unpacking please contact your local distributor immediately You can find the necessary contact details on page ii in this manual Available accessories ABL sells addition...

Page 12: ...de the charging station pictured Please contact your local distributor if you require additional information about these components or would like to place an order CAUTION Please note that the do it y...

Page 13: ...formation from your electrical contractor or your distributor The charging station must be installed where it is freely accessible to all authorized users Ideally the mounting site should already prov...

Page 14: ...x 222 mm H x W The mounting area must have an even surface that provides suf ficient stability for installing the eMH1 Choose a mounting site that allows you to reach the charging socket of your vehi...

Page 15: ...Keep the screws in a safe place as you will need them again to complete installa tion 3 Pull off the front part of the housing 4 Remove the plastic tongue intended for the power supply in the lower s...

Page 16: ...eacti vated during installation Otherwise there is a danger of electric shock n addition depending on your model variant please deactivate the integrated or exter nal residual current circuit breaker...

Page 17: ...lete installation 1 Replace the upper part of the housing 2 Fix the upper part of the housing to the rear part using the appropriate screws 3 Switch the integrated or onsite FI residual current circui...

Page 18: ...station The charging socket of the EVSE 5X2 has an electromechani cal locking mechanism which secures the charging plug in place as soon as the charging cable is connected to the vehicle As long as t...

Page 19: ...and housing do not show any observable damage Normal operation On the right side of the housing the EVSE 5X2 is fitted with a charging socket accord ing to IEC 62196 2 Type 2 with electromechanical l...

Page 20: ...Check the two indicator LEDs on the top part of the EVSE 5X2 When the charging station is ready for operation the green LED indicator will flash briefly every 5 sec onds while the blue LED will be not...

Page 21: ...perating states the LEDs may be illuminated continuous ON flash be extinguished continuous OFF During normal operation the following operating states are shown DESCRIPTION flashes every 5 seconds OFF...

Page 22: ...cted The EVSE 5X2 reinitiates the charging procedure every 30 seconds checking commu nications with the vehicle If the error recurs the indicator LEDs continue to show the error code No charging occur...

Page 23: ...d Check the status of the RCCB and if necessary switch it back on using the pivot lever The indicator LEDs of the EVSE 5X2 are faulty Should the indicator LEDs of the EVSE 5X2 be faulty they must be r...

Page 24: ...wn see page 18 Proceed as follows to test the RCCB 1 Open the cover shield of the charging station using the key supplied 2 Locate the button engraved T or marked Test 3 Press the button The RCCB shou...

Page 25: ...n addition switch off the miniature circuit breaker MCB in your upstream domes tic power distribution box position 0 5 Now the EVSE 5X2 is completely free of electricity and may be demounted if re qui...

Page 26: ...protection devices RCCB Type A 30 mA and electronic DC fault current detector DC RCM I n d c 6 mA RCCB Type A 30 mA RCCB Type B 30 mA Energy meter not included Control Customization internal RS485 in...

Page 27: ...5 to 95 no condensation Class of protection I Degree of protection housing IP44 Overvoltage category III II Dimensions 272 x 220 x 106 mm H x W x D Weight per unit ca 2 3 kg WARNING Please note that...

Page 28: ...art 22 AC charg ing station for electric vehicles HD 60364 7 722 2012 Low voltage installations Part 7 722 Power supply for electric vehicles Classes of protection Degrees of protection CLASS OF PROTE...

Page 29: ...g device for detecting DC fault cur rents GSM Global System for Mobile Communi cations Standard for fully digital mobile networks HEV Hybrid Electric Vehicle Hybrid vehicle combination of a classic co...

Page 30: ...i cal contractor who will connect the device to the local power supply Illustration not to scale of the drilling template included You may however carry out the mechanical installation of the charging...

Page 31: ...for the country in which the product was purchased Should the product be operated in another country the legal provisions of the country of purchase apply nevertheless Under no circumstances are guar...

Page 32: ...guarantee of marketability or suitability for spe cific uses are restricted to the warranty period Disposal advice The crossed out trash can symbol indicates that electrical and elec tronic devices i...

Page 33: ...29...

Page 34: ...MADE IN GERMANY Albert B ttner Stra e 11 D 91207 Lauf Pegnitz Tel 49 0 9123 188 0 Fax 49 0 9123 188 188 info abl de www abl de ABL SURSUM Bayerische Elektrozubeh r GmbH Co KG...

Reviews: