8
PB
Press the
<SET>
soft key to open the
PV Trigger’s TIME
and
VOLT
(age) set menus.
To adjust the voltage, press the
<VOLT>
soft key.
Adjust the voltage within a range of 20V-150V by
pressing the
< - >
or
< + >
soft key. When finished,
press the
<BACK>
soft key to return to the
PV Trigger
screen
To adjust the minimum amount of time the PV voltage
must remain high before deactivating the
AUX MODE
,
press the
<TIME>
soft key.
AUX MODE
PV Trigger
Output: On On
EXIT NEXT SET MODE
PV VOLTS
>140
BACK - +
AUX MODE
PV Trigger
EXIT TIME VOLT
AUX MODE
PV Trigger
EXIT TIME VOLT
g
g
g