11
Manuale CSG II MP -
English
3.3.5
Using the device without tightening the front ring nut properly, or worse without the front nut. (CSG II MP 450)
3.3.6
Do not use the applicator without the cartridge inside the holder (models with holder).
3.3.7
Do not cover the rear exhaust air outlet holes or on the pneumatic return switch.
3.3.8
Never use in environments where dusts or other volatile materials are present, especially if inflammable.
3.3.9
Never immerse the gun in solvents or acids.
3.3.10
When cleaning the machine , never use hydrogenated hydrocarbons based solvents and/or detergents
(1.1.1 Ethyl trichloride, methylene chloride, etc.) as they could oxidize the galvanized components thus triggering chemical
reactions also of explosive nature; never use highly acid or basic substances when cleaning.
3.3.11
Do not hold the gun less than 30 cm from your face during use, during release of the lever or when using the pneumatic
return. The blast of air exiting the exhaust air outlet holes (1) and the return valve is powerful and may be cause injury.
3.3.12 Do not point the gun at yourself, other people, animals, plants or anything other than the object to be treated.
3.3.13
Replenishing, cleaning and maintaining without having isolated or disconnected the compressed air supply
from the applicator.
3.3.14
Exceeding 10 bar / 145 PSI at the device’s inlet.
3.3.15
Do not modify or tamper with the applicator in any way or remove any of its parts.
4. START-UP
to be carried out by the operator
Pressure reducer
with filter and gauge
Ø 6 mm
Fast tap
Max. tube length: 10 m.
Operating pressure: 4-8 bar
58/116 PSI
Before gun start-up and usage, wear the recom-
mended individual safety devices:
• Safety gloves
• Ear defenders
• Safety glasses
4.1 Air feeding system
Connect the machine to a compressed air system featuring the following characteristics:
• Max. air humidity 5%; • Air temperature from -10° C to +70° C • System capacity 500 l/min at least • System equipped with
lubricator, pressure reducer and gauge.Lubrication must be: 3-4 drops of lubricant every 1000 l/min.
The machine is equipped with a ¼ gas male threaded connector, to which connection is possible according to specific needs.
The tube shall be a wound conductive tube for dynamic laying with resistance lower than 1 Mega Ohm and bursting pressure at
least twice the maximum pressure of the system. Air consumption is reduced and proportional to the number of times in which
the product supply lever is released.
4.2 Bag refill
to be carried out by the operator
Always disconnect the device from the air supply when replacing the cartridge and whenever the front ring nut is unscrewed from the
tube (CSG II MP 450), in order to prevent accidental pressure on the control lever causing injury through crushing, expulsion of
materials or other dangerous situations.
Always control the refill material expiry date.
Never introduce damaged or not fully intact bags or cartridges in the gun.
2
4.2.3
13
4.2.3 a
4.2.3
4.2.4a
2
2
2
13