159
11. CHECKS TO MAKE ON THE MACHINE AFTER REPAIRS
11.1 C
HECKING THE CORRECT FUNCTIONING OF CONTROLS
‑
Check from the ground that the controls smoothly activate the machine.
‑
For the correct functioning of controls, refer to the relating paragraph.
11.2 C
HECKING FUNCTIONING OF THE SAFETY DEVICES
Check that all safety devices function as stated in this manual.
BOOM LIFT MODELS X17J
JLG
X17JR0420113
PROBLEMS
CAUSES
SOLUTIONS
At the end of the job it is not
possible to de‑stabilise the
equipment
• The aerial part has not been
put perfectly into the rest
position
• The photocells are
faulty/incorrect
• Repeat the procedure for
putting the aerial part of the
machine to rest and check
the correct signal from the
photocells
During use of the aerial part
vibrations and unsteadiness
in the extension manoeuvre
and work arm retraction
speed are detected
• Telescopic arm and slide
blocks are sparsely lubricated
• Slide blocks worn
• Lubricate arm and slide
blocks
• Adjust slide blocks
The work platform does not
remain level during move‑
ment of the arm
• Air in the levelling system
• The balancing valve on the
levelling plant is faulty
or is not calibrated
• Bleed the air from the
work platform levelling
system (consult our technical
after‑sales service)
•Replace the work platform
levelling plant balancing
valve.
The movement of the first
and second arm is not regu‑
lar
• Accumulator discharged
• Replace the accumulator
(consult our technical after‑
sales service).
Summary of Contents for X17J
Page 2: ......
Page 43: ...X17JR0420113 BOOM LIFT MODELS X17J JLG 39 ...
Page 72: ...6 3 WORKING AREA X17JR0420113 68 BOOM LIFT MODELS X17J JLG Rotation 360 Rotation 360 ...
Page 121: ...117 BOOM LIFT MODELS X17J JLG X17JR0420113 ...
Page 166: ...12 2 HYDRAULIC SYSTEM DIAGRAM LITHIUM VERSION X17JR0420113 162 BOOM LIFT MODELS X17J JLG ...
Page 170: ... LITHIUM VERSION X17JR0420113 166 BOOM LIFT MODELS X17J JLG ...