OSANG Healthcare Infopia Clover A1c Instructions For Use Manual Download Page 11

20

21

11. TESTING HbA1c

Capillary whole blood obtained from a fingertip can be used for HbA1c test.

A 4uL blood sample is needed for the HbA1c.

Sample Collection and Handling.

Sample Collecting Area of Reagent Pack

- Capillary Blood Process

Prick the fingertip of the patient to get a minimum of 4uL of capillary blood sample, and 

touch softly the blood sample with the capillary tip of the Reagent Pack. The blood is 

automatically drawn up. Make sure that the sample area is completely filled.

IMPORTANT

 : Once the reagent pack is filled with the blood sample, analysis must  

                        begin immediately.

11. TESTING HbA1c

- Venous Blood Process

Venous whole blood collected in tubes with K

2

 ∙ K

EDTA, lithium heparin, sodium citrate 

or sodium fluoride/ oxalate as anticoagulants can be used.

Venous whole blood can be stored at 2~8

 (36~46

) for 7 days with unbroken seal 

(only 3 days when seal is broken) and at 20~25 

 (68~77

) for 3 days. 

Allow blood samples to reach room temperature. Anti-coagulated blood should be mixed 

well prior to testing. Remove the stopper from the holder and take out a drop of blood 

sample on a clean container. Softly touch the sampling area of the reagent pack on the 

blood sample, and wait until the sampling area is completely filled.

NOTE :

 Do not wipe off excess blood outside the sampling area.

              Do not touch the open end of the sampling area. 

CAUTION :

 There is a potential risk of biological hazard. 

All part of the 

CLOVER A1c

®

 system should be considered potentially infectious. 

• Use gloves.

• Dispose of used test cartridges in a sturdy container with lid.

• Follow all hygiene and safety regulations in force locally.  

Summary of Contents for Infopia Clover A1c

Page 1: ......

Page 2: ...IPTION 7 LIST OF ICONS 8 INSTALLATION 9 OPERATION 10 SETTING THE ANALYZER 11 TESTING HbA1c 12 REVIEWING RESULTS 13 CHECKING THE SYSTEM 14 OPTION 15 TROUBLESHOOTING 16 SPECIFICATION 17 MAINTENANCE 18 S...

Page 3: ...ermined by the measurement of Hemoglobin A1c The ADA American Diabetes Association recom mends measurement of the Hemoglobin A1c levels of two to four times per user with less frequency in patients wi...

Page 4: ...F and at a relative humidity between 10 to 90 1 CLOVER A1c Analyzer 2 Instructions for Use 3 Exclusive Power Adapter 4 Fan Filters 5 Daily Check Cartridge 6 Monthly Check Cartridge WARNING Do not modi...

Page 5: ...alyzer Insert Reagent Pack Insert Check Cartridge Insert Check reagent pack into the analyzer Insert Check Reagent Pack Analyzer is under Check Mode Insert Check Cartridge into the analyzer 7 LIST OF...

Page 6: ...n disturb internal calibrated optics and electronics or cause other damages Always handle the system with care The CLOVER A1c Self is a precision system and must be handled accordingly Connect the Sys...

Page 7: ...CLOVER A1c performs hardware functionality test to verify that the internal optics and the mechanical system are operating correctly 13 03 30 AM10 00 Set up Memory DATE yy mm dd TIME 12h 13 03 30 AM...

Page 8: ...ed by pressing the Gor then press 10 SETTING THE ANALYZER Printer mode Once the printer option is selected choose either Automatic or Manual by pressing the Gand Garrows Automatic Result is printed au...

Page 9: ...he Warming up PROCEDURE Test Procedure STEP 1 Warming up While warming up the CLOVER A1c performs hardware funtionality test to verify that the internal optics and the mechanical system are operating...

Page 10: ...nalyzer The cartridge is designed to fit only in one way 13 03 30 AM10 00 13 03 30 AM10 02 13 03 30 AM10 02 Gently mix the reagent pack 5 6 times before applying blood sample STEP 5 1 Apply the blood...

Page 11: ...trate or sodium fluoride oxalate as anticoagulants can be used Venous whole blood can be stored at 2 8 36 46 for 7 days with unbroken seal only 3 days when seal is broken and at 20 25 68 77 for 3 days...

Page 12: ...easuring time is 5 minutes and the test result will be displayed in or mmol mol STEP 8 After the test is completed open the analyzer lid Remove cartridge will be shown Remove the test cartridge from t...

Page 13: ...08 AM10 08 Test OK Cartridge 13 03 30 13 03 30 CODE OK 3961 11 TESTING HbA1c Limitation of Procedure The CLOVER A1c assay gives accurate and precise results over a range of total Hemoglobin of 7 to 20...

Page 14: ...y then press STEP 1 Set up Memory 12 REVIEWING RESULTS The test results will appear chronologically starting with the most recent date Press the Gand Gbuttons to scroll through STEP 2 13 11 02 PM12 05...

Page 15: ...before use Precautions Warnings For In Vitro Diagnostic use Do not use the Check Cartridge beyond the expiration date printed on the Check Cartridge Label and Pouch Do not use the Check Cartridge if s...

Page 16: ...mode press Gfor 3 seconds 13 03 30 13 03 30 13 03 30 13 CHECKING THE SYSTEM 4 Close the lid The test starts automatically 5 After 1 mimute OK or error message will be displayed 6 Press and remove the...

Page 17: ...se the Monthly Check Cartridge When there is a concern that the test result may be incorrect After an error message Er 4 or Er 5 Once a month before samples are tested The Monthly Check Cartridge used...

Page 18: ...wait until they disappear 6 Close the lid The test starts automatically 13 03 30 13 03 30 13 03 30 13 CHECKING THE SYSTEM 7 After 5 minutes OK or error message will be displayed 8 Press and remove the...

Page 19: ...technical support 1 Open the lid of the CLOVER A1c analyzer How to test with the Control Solution 3 Mix the reagent pack gently 5 6 times and touch softly the control solution with the tip of samplin...

Page 20: ...esh bottle of control solution Contact your local representative for customer support 5 9 41 mmol mol No 030 13 11 02 AM11 45 ID 14 OPTIONS Printer in manual mode STEP 1 Press the printer button after...

Page 21: ...analyzer is pre set to use the barcoding system appropriately during the set up process Please refer to page 20 The barcode scanner can be used to scan the patients ID All the patients information is...

Page 22: ...e label The background reflection is too high or low 13 03 30 14 OPTIONS STEP 1 Connect the USB Cable from the analyzer to the PC while in stand by mode STEP 2 Once connected the analyzer will display...

Page 23: ...cognize the solutions within the reagent pack The reagent pack may be damaged and leak reagent solution Please press button and remove the cartridge Insert a new test cartridge and perform the test ag...

Page 24: ...dge Test or Monthly Check Cartridge Please press mode button and remove the cartridge Check whether the cartridge is reused or not Insertanewcartridgeandperformthetestagain If the problem persists con...

Page 25: ...knobs to rotate the cartridge compartment forward STEP 3 Dampen a sponge swap with water or ethanol STEP 4 Gently wipe the cartridge compartment Be careful not to drip any liquids into the system Clea...

Page 26: ...he analyzer with any metallic or inflammable materials 9 Keep away from strong electromagnetic fields 10 Do not install near any potential electromagnetic sources 19 DISPOSAL Analyzer must be disposed...

Page 27: ...The bead inside the Reagent Solution of the Reagent Pack might sink and coagulate Gently mix the Reagent Pack before testing and visually check that the beads are not coagulated 10 50 Check Reagent S...

Page 28: ...e cartridge not be absorbed fully into absorption pad 3 If bead is not accumulated fully in the bead window If the bead is accumulated just like half sized an so on 4 If the cartridge has residue or s...

Page 29: ...56 21 SYMBOL DESCRIPTION Date of Manufacturer Keep away from sunlight Do not reuse Direct Current Waste Electrical and Electronic Equipment Symbol Description Biohazard...

Page 30: ......

Page 31: ...FH02B OSANG Healthcare Co Ltd 132 Anyangcheondong ro Dongan gu Anyang si Gyeonggi do Korea 14040 www osanghc com Obelis S A Bd General Wahis 53 1030 Brussels Belgium Tel 32 2 732 59 54 Fax 32 2 732 60...

Reviews: