Environmental condition for installation
-SinceMPDPpanelisverysensitiveforphysicalimpact,installationrequires
considerablecaution.
-Minimumclearance(20cm)mustbesecuredforsmoothventilation.(SeeP14~15)
Installationmustavoidairtightornearairtightplaces.Improperventilationcauses
malfunctionandshortensproductlifetimebyrapidinternaltemperaturerise.If
MPDPhastoinstalledattheimproperventilation,additionalventilationopenings
orfansmustbeprovidedtokeeptheinternaltemperaturebetween0~35℃.
-ForgroundofMPDPandapplicationdevices,itshouldbeconnectedasframe
ground.
-ConsideringMPDPMaxpowerconsumption,checkthemainelectric
specification.
Consideration for easier service
-WhenyoudesigntheexteriordesignforMPDPsystem,considereasier
disassemblyforpossibleserviceoccasioninthefuture.
-TheslidingUniversalUnitofORIONPDPisrecommendedforeasierservice.
-IfservicepeoplecanstepintothebacksideofMPDPsystem,itcangreatly
reducetimeandeffortforservice.
-Incaseofhigherlocations,considertheinstallationlocationandexteriordesign
foreasierservice.
※Cautions for consisting MPDP System
The number of Daisy chain connection
-Theimagequalitycanbevarydependonthequalityofsignalandcable
condition.
INPUT SOURCE
Resolution
Connection
Remark
DVI
1600x1200x60HZ
6sets
HDCPAvailable
RS-232C
30sets
ORIONCableOnly
-IfyouneedtousemoreMPDPsetsthanindicatedinthetable,usingaDVI
distributorishighlyrecommended.
Cautions for using Wall controller and Application devices
-IfyouuseMVP,Crestron,Extron,AMX,orJupitordevicesinsteadofMSCS,MPDP
ControlProgram,toconsistmultiscreen,APLfunctionmustbeturnedoffto
preventpossiblebrightnessdifferencebetweensets.
Caution for the other control program besides MPDP
Control Program (MSCS)
-Ifyouwanttouseautomaticpoweron/offfunctionthatmakeMPDPturnedon/
offbyconnectingmainpower,allowatleast20secondsofStand-bytimebefore
MPDPisturnedon,whenyoumakecontrolprogram.
-BICfunctionrequirestwo-waycommunication.IfyoudonotuseMSCS,therewill
bewhitebalancedifferencebyglobaldataastimeelapses.Toavoidsucherror,
NewMFCmustbeused.
-IfRS-232Ccommunicationsignalorotherimagesignalisappliedto9ormore
setssimultaneously,communicationalerrormayoccur.(Poweron&Broadcast)