![Orion OPM-4250 User Manual Download Page 10](http://html1.mh-extra.com/html/orion/opm-4250/opm-4250_user-manual_1652680010.webp)
- 16 -
OPM-4250 | OPM-4250R
- 17 -
Infinitely Expandable
guidance for Users
3.
input/Output Terminals
DOWN
UP
ID SELECT
RS-232C
INPUT
OUTPUT
DVI-D_2
DVI-D_1
OUTPUT
INPUT
OUTPUT
INPUT
• Model Name : OPM-42
50
• Voltage : AC~100 - 240V
• Current : Max. 4A
• Frequency : 50/60Hz
• Serial No :
PDPCO., LTD.
Made in Korea
To prevent electric shock,
Do not remove cover.
No user serviceable part inside Refer
servicing to qualified service personal.
FCC Verified : Class "A"
CAUTION
ID SELECT
M-STB
M-ON
FAN
S-ON
RS-232C
INPUT
OUTPUT
DVI-D_2
DVI-D_1
OUTPUT
INPUT
OUTPUT
INPUT
❶
❷
❸
❹
❺
1.RS-232C
MPDPControl,Firmware
Upgrade,9pinD-sub
2.DVI 1
TMDSSignal
3.DVI 2
TMDSSignal
4.ID Switch
SetIDSwitch
5.AC Input
AC100V~240V,50/60Hz
DOWN
UP
ID SELECT
RS-232C
INPUT
OUTPUT
DVI-D_2
DVI-D_1
OUTPUT
INPUT
OUTPUT
INPUT
• Model Name : OPM-42
50
• Voltage : AC~100 - 240V
• Current : Max. 4A
• Frequency : 50/60Hz
• Serial No :
PDPCO., LTD.
Made in Korea
To prevent electric shock,
Do not remove cover.
No user serviceable part inside Refer
servicing to qualified service personal.
FCC Verified : Class "A"
CAUTION
Set iD Switch Setting
ExampleofIDSwitchsetting
y
-YoucansetIDwith3rotaryswitchesasshowninthefollowingfigure.
LED indication
y
※ When you set iD of MPDP set, power cable must be disconnected. if power cable is not disconnected
during iD setting, MPDP set may be operated with the previous iD and it may cause abnormal behavior.
※ For stable operation, wait for at least 10 seconds prior to use MPDP control program after the first AC
power connection.
LED Indication
Description
0 12
3
45
67
8
9
0 12
3
45
67
8
9
0 12
3
45
67
8
9
M-STB
M-ON
FAN
S-ON
No Power.
0 12
3
45
67
8
9
0 12
3
45
67
8
9
0 12
3
45
67
8
9
M-STB
M-ON
FAN
S-ON
Internal System Check after Power on.
0 12
3
45
67
8
9
0 12
3
45
67
8
9
0 12
3
45
67
8
9
M-STB
M-ON
FAN
S-ON
System ready.
0 12
3
45
67
8
9
0 12
3
45
67
8
9
0 12
3
45
67
8
9
M-STB
M-ON
FAN
S-ON
Power ON by MSCS Program.
(M-ON and S-ON LEDs blink every other
second. Power on status)
0 12
3
45
67
8
9
0 12
3
45
67
8
9
0 12
3
45
67
8
9
M-STB
M-ON
FAN
S-ON
Power Off by MSCS Program.
(System ready).
M-ON(Master-ON) : IP Board Master Power On.
FAN : FAN POWER ON, IF Red LED on IP board is turned on, please check FANs.
※ To protect the product, power can be disconnected automatically when the fan is stopped.
M-STB(Master-
Stand By
) : IP Board Master Ready
S-ON(Slave-ON) : IP Board Slave Ready
ON OFF
[PDP ID 01]
0 12
3
45
67
8
9
0 12
3
45
67
8
9
0 12
3
45
67
8
9
[PDP ID 15]
0 12
3
45
67
8
9
100digit10digitsingledigit
100digit10digitsingledigit
Summary of Contents for OPM-4250
Page 45: ...86 OPM 4250 OPM 4250R Memo...