![Orion OPM-4250 User Manual Download Page 33](http://html1.mh-extra.com/html/orion/opm-4250/opm-4250_user-manual_1652680033.webp)
- 62 -
OPM-4250 | OPM-4250R
- 63 -
Infinitely Expandable
"Multi-Scale" Communication Sequence
-
*Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
*Commandsequence:Slave
Master.
Muti-Scale Command transmission (to Slave)
→
←
Muti-Scale Response transmission (from Slave)
Muti-Scale Command transmission (to Master)
→
←
Muti-Scale Response transmission (from Master)
infomation
3.4.
Command for displaying the information on the screen (Input source and resolution by OSD)
-
It is available only on Power On (Operative) status.
-
Send to MPDP
-
Normalcommand
A.
STX
CMD
Length
Data
ETX
ID
M/S
Value
0x02
0x42
0x02
Variable
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
Broadcastcommand
B.
STX
CMD
Length
Data: ID
ETX
Value
0x02
0x42
0x01
0x00
0x03
*MakeallPDP(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MPDP
-
STX
CMD
Length
Data
Check Sum
ETX
ID
M/S
Value
0x02
0x40
0x02
Variable
Variable
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
"Information" Communication Sequence
-
*Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
*Commandsequence:Slave
Master.(ExceptforBroadcastcommand)
Information Command transmission (to Slave)
→
←
Information Response transmission (from Slave)
Information Command transmission (to Master)
→
←
Information Responsetransmission (from Master)
input-Mode Change
3.5.
Command for changing input mode without screen scaling
-
It is available only on Power On (Operative) status.
-
CMD: 0x44 (DVI 1), 0xDC (DVI 2)
-
Send to MPDP
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
M/S
Value
0x02
Variable
0x02
Variable
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
BroadcastCommand
B.
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallPDP(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MPDP
-
STX
CMD
Length
Data
Check Sum
ETX
ID
M/S
Value
0x02
Variable
0x02
Variable
Variable
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
"Input-Mode Change" Communication Sequence
-
*Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
*Commandsequence:Slave
Master.(ExceptforBroadcastcommand)
Input-Mode Change Command transmission (to Slave)
→
←
Input-Mode Change Response transmission (from Slave)
Input-Mode Change Response transmission (to Master)
→
←
Input-Mode Change Response transmission (from Master)
Auto-Power Mode
3.6.
Configuration for automatic power on by AC power connection.
-
It is available only on Power On (Operative) status.
-
CMD: 0x62(Set), 0x63(cancel)
-
Send to MPDP
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
M/S
Value
0x02
Variable
0x02
Variable
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
Summary of Contents for OPM-4250
Page 45: ...86 OPM 4250 OPM 4250R Memo...