![Orion OLM-4610 User Manual Download Page 4](http://html1.mh-extra.com/html/orion/olm-4610/olm-4610_user-manual_1652673004.webp)
Environmental condition for installation
- Since MLCD panel is very sensitive for physical impact, installation requires considerable
caution.
- Minimum clearance(20cm) must be secured for smooth ventilation. (See page 6,
16~17)Installation must avoid air tight or near air tight places. Improper ventilation
causes malfunction and shortens product lifetime by rapid internal temperature rise. If
MLCD has to installed at the improper ventilation, additional ventilation openings or fans
must be provided to keep the internal temperature between 0 ~ 35˚C.
- For ground of MLCD and application devices, it should be connected as frame ground.
- Considering MLCD Max power consumption, check the main electric specification.
Recommended Operating Condition
- Temperature: 5~35˚C, Humidity: 35~75%, Suitable operating time : under 12 hours a day.
- Do not install the set at the air-tight condition.
- It is recommended to install the set with good ventilation.
- Do not install the set at the place of direct sunlight or excessive exposure to lightings.
※
Blackening, stains or burning effect on the screen can be occurred by improper
installation or use against the above recommended conditions.
Consideration for easier service
- When you design the exterior design for MLCD system, consider easier disassembly for
possible service occasion in the future.
- The sliding Universal Unit of ORION is recommended for easier service.
- If service people can step into the backside of MLCD system, it can greatly reduce time
and effort for service.
- In case of higher locations, consider the installation location and exterior design for easier
service.
※
Cautions for consisting MLCD System
The number of Daisy chain connection
- The image quality may vary depend on the quality of signal and cable condition.
INPUT SOURCE
Resolution
Connection
Remark
DVI
1600 x 1200 x 60Hz
6 sets
HDCP Available
PC
1600 x 1200 x 60Hz
3 sets
Video
NTSC, PAL, SECAM
6 sets
RS-232C
30 sets
ORION Cable Only
- If you need to use more MLCD sets than indicated in the table, using a DVI distributor is
highly recommended.
Caution for the other control program besides MLCD
Control Program (MSCS)
- If you want to use automatic power on/off function that make MLCD turned on/off by
connecting main power, allow at least 20 seconds of Stand-by time before MLCD is turned
on, when you make control program.
- If RS-232C communication signal or other image signal is applied to 9 or more sets
simultaneously, communicational error may occur. (Power on & Broadcast)
- 4 -
- 5 -
ORION
Infinitely Expandable
W
ARNING
W
ARNING
MLCD