- 68 -
- 69 -
ORION
Infinitely Expandable
3.7. Auto-Power Mode
-
Configuration for automatic power on by AC power connection.
-
It is available only on Power On (Operative) status.
-
CMD: 0x62(On), 0x63(Off)
-
Send to MLCD
A. NormalCommand
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
B. BroadcastCommand
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*AllLCDwilldothesameoperationsimultaneously.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area..
3.8. DTV Over-Scan On/Off
-
Users can select Over-scan when input is DTV resolution from DVI. It is only available with DVI mode.
-
It is usable only at Power on status.
-
CMD: 0xE4(On), 0xE5(Off)
-
Send to MLCD
A. NormalCommand
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
B. BroadcastCommand
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.9. Over-Temperature Shut-down Control
-
Commands for automatic power off making MLCD set stand-by and OSD warning method, if IP board
temperature is 95℃ or higher.
-
It is available only on Power On (Operative) status.
-
The initial configuration is "Over Temperature Shut-down Enable."
-
CMD
*0x64(OverTemperatureShut-downEnable)
:IncaseIPboardtemperatureis95℃orhigher,displaywarningsignal"HighTemperature"inredfor1minuteatthelowerleft
cornerofMLCDandpoweroffautomatically(Stand-bymode.)
*0x65(OverTemperatureShut-downDisable)
:IncaseIPboardtemperatureis95℃orhigher,displaywarningsignal"HighTemperature"inredfor3secondsatthelowerleft
cornerofMLCDandrepeatthewarningevery60seconds.(Noautomaticpoweroff)
-
Send to MLCD
A. NormalCommand
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0x01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
B. BroadcastCommand
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0x01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:AddthesumfromSTXtoDataandexecute"Not"operation.
3.10. Test Pattern
-
Command for checking the operating status with internal patterns
-
It is available only on Power On (Operative) status.
-
CMD: 0x57 (Red), 0x58 (Green), 0x59 (Blue), 0x5A (White), 0x5B (Screen)
-
Send to MLCD
A. NormalCommand
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
B. BroadcastCommand
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
MLCD