- 70 -
- 71 -
ORION
Infinitely Expandable
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.11. FAN Mode
-
Command for FAN control
-
It is available only on Power On (Operative) status.
-
CMD: 0xD8
-
Send to MLCD
A. NormalCommand
STX
CMD
Length
Data
ETX
ID
Master
Control
Value
0x02
0xD8
0x02
Variable
0x01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*Control:Auto(0x00),Full(0x01)
B. BroadcastCommand
STX
CMD
Length
Data
ETX
ID
Control
Value
0x02
0xD8
0x02
0x00
Variable
0x03
*But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MLCD
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
0xD8
0x02
Variable
0x01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.12. Elapsed Time
-
Command for informing the elapsed time of each LCD set. (Basic unit: hour)
-
It is available only on Power On (Operative) status.
-
CMD : 0x77 (Get), 0x7B (Initial)
-
Send to MLCD
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*Itisnotapplicableas"Broad-cast"command
-
Receive from MLCD
STX
CMD
Length
Data
Check
Sum
ETX
ID
Master
Elapsed Time
Value
0x02
Variable
0x08
Variable
0X01
…
Variable
0x03
Hundred
thousands
ten thou-
sands
thousands
hundreds
ten
one
Variable
Variable
Variable
Variable
Variable
Variable
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
*ElapsedTime
-Hundredthousands,tenthousands,thousands,hundreds,tens,ones:0(0x00)~9(0x09)rangevalue.
3.13. IP Serial Number
-
Command for assigning and identifying the serial numbers of each IP board. (8 digit)
-
CMD: 0x75 (Get S/N), 0x76 (Set S/N)
-
Send to MLCD
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*"Get/SetIPSerialNumber"(0x75/0x76)commandisnotapplicableas"Broad-cast"command,becauseeachLCDshouldhavean
uniqueserialnumber.
-
Receive from MLCD
STX
CMD
Length
Data
Check
Sum
ETX
ID
Master
SN
Value
0x02
Variable
0x0A
Variable
0x01
…
Variable
0x03
0
1st
2nd
3rd
4th
5th
6th
7th
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
*ElapsedTime
-0,1st,2nd,3rd,4th,5th,6th,7th:0(0x00)~9(0x09)rangevalue
3.14. Get Current Status
-
Command for obtain the current LCD (IP) information
-
It is available only on Power On (Operative) status.
-
CMD: 0x87
-
Send to MLCD
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
0x87
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*Itcannotbeusedas"Broad-cast"command.
MLCD