- 58 -
ORION PDP
- 59 -
Infinitely Expandable
Over-Temperature Shut-down Control
3.9.
Commands for automatic power off making MLCD set stand-by and OSD warning method, if IP board
-
temperature is 95℃ or higher.
CMD
-
*0x64(OverTemperatureShut-downEnable)
:IncaseIPboardtemperatureis95℃orhigher,displaywarningsignal"HighTemperature"inredfor1minuteatthelowerleft
cornerofMLCDandpoweroffautomatically(Stand-bymode.)
*0x65(OverTemperatureShut-downDisable)
:IncaseIPboardtemperatureis95℃orhigher,displaywarningsignal"HighTemperature"inredfor3secondsatthelowerleft
cornerofMLCDandrepeatthewarningevery60seconds.(Noautomaticpoweroff)
It is available only on Power On (Operative) status.
-
The initial configuration is "Over Temperature Shut-down Enable."
-
Send to MLCD
-
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0x01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
Receive from MLCD
-
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0x01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:AddthesumfromSTXtoDataandexecute"Not"operation.
Test Pattern
3.10.
Command for checking the operating status with internal patterns
-
It is available only on Power On (Operative) status.
-
CMD: 0x57 (Red), 0x58 (Green), 0x59 (Blue), 0x5A (White), 0x5B (Screen)
-
Send to MLCD
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommand
B.
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD
-
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
Fan Mode
3.11.
Command for FAN control
-
It is available only on Power On (Operative) status.
-
CMD: 0xD8
-
Send to MLCD
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
Master
Control
Value
0x02
0xD8
0x02
Variable
0x01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*Control:Auto(0x00),Full(0x01)
BroadcastCommand
B.
STX
CMD
Length
Data
ETX
ID
Control
Value
0x02
0xD8
0x02
0x00
Variable
0x03
*But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD
-
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
0xD8
0x02
Variable
0x01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
Elapsed Time
3.12.
Command for informing the elapsed time of each LCD set. (Basic unit: hour)
-
It is available only on Power On (Operative) status.
-
CMD : 0x77 (Get), 0x7B (Initial)
-
Send to MLCD
-
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*Itisnotapplicableas"Broad-cast"command
Receive from MLCD
-
STX
CMD
Length
Data
Check
Sum
ETX
ID
Master
Elapsed Time
Value
0x02
Variable
0x08
Variable
0X01
…
Variable
0x03
Hundred
thousands
ten thou-
sands
thousands
hundreds
ten
one
Variable
Variable
Variable
Variable
Variable
Variable
MLCD