Environmental condition for installation
-SinceMLCDpanelisverysensitiveforphysicalimpact,installationrequires
considerablecaution.
-Minimumclearance(20cm)mustbesecuredforsmoothventilation.(SeeP12~13)
Installationmustavoidairtightornearairtightplaces.Improperventilationcauses
malfunctionandshortensproductlifetimebyrapidinternaltemperaturerise.If
MLCDhastoinstalledattheimproperventilation,additionalventilationopenings
orfansmustbeprovidedtokeeptheinternaltemperaturebetween0~35℃.
-ForgroundofMLCDandapplicationdevices,itshouldbeconnectedasframe
ground.
-ConsideringMLCDMaxpowerconsumption,checkthemainelectricspecification.
Consideration for easier service
-WhenyoudesigntheexteriordesignforMLCDsystem,considereasier
disassemblyforpossibleserviceoccasioninthefuture.
-TheslidingUniversalUnitofORIONPDPisrecommendedforeasierservice.
-IfservicepeoplecanstepintothebacksideofMLCDsystem,itcangreatly
reducetimeandeffortforservice.
-Incaseofhigherlocations,considertheinstallationlocationandexteriordesign
foreasierservice.
※
Cautions for consisting MLCD System
The number of Daisy chain connection
-Theimagequalitymayvarydependonthequalityofsignalandcablecondition.
INPUT SOURCE
Resolution
Connection
Remark
DVI
1600x1200x60Hz
6sets
PC
1600x1200x60Hz
3sets
Video
NTSC,PAL,SECAM
6sets
RS-232C
30sets
ORIONCableOnly
-IfyouneedtousemoreMLCDsetsthanindicatedinthetable,usingaDVI
distributorishighlyrecommended.
Caution for the other control program besides MLCD
Control Program (MSCS)
-Ifyouwanttouseautomaticpoweron/offfunctionthatmakeMLCDturnedon/
offbyconnectingmainpower,allowatleast20secondsofStand-bytimebefore
MLCDisturnedon,whenyoumakecontrolprogram.
-IfRS-232Ccommunicationsignalorotherimagesignalisappliedto9ormore
setssimultaneously,communicationalerrormayoccur.(Poweron&Broadcast)
- 4 -
ORION PDP
W
arning
- 5 -
Infinitely Expandable
W
arning
MLCD