- 56 -
ORION PDP
- 57 -
Infinitely Expandable
input-Mode Change
3.5.
Command for changing input mode without screen scaling
-
It is available only on Power On (Operative) status.
-
CMD: 0xDD(DVI), 0XDE(PC), 0XE2(Video)
-
Send to MLCD
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
Master
XY
X
Value
0x02
Variable
0x04
Variable
0X01
0X11
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommand
B.
STX
CMD
Length
Data
ETX
ID
XY
S
X
Value
0x02
Variable
0x04
0x00
0x11
0x00
0x01
0x03
*AllLCDwilldothesameoperationsimultaneously.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD
-
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
global Offset
3.6.
Command for removing the image data in seam area (On) or displaying all the data on the screen (Off)
-
It is available only on Power On (Operative) status.
-
CMD: 0x74(On), 0x73(Off)
-
Send to MLCD
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommand
B.
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCD(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD
-
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
auto-Power Mode
3.7.
Configuration for automatic power on by AC power connection.
-
It is available only on Power On (Operative) status.
-
CMD: 0x62(On), 0x63(Off)
-
Send to MLCD
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommand
B.
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*AllLCDwilldothesameoperationsimultaneously.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD
-
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area..
DTV Over-Scan On/Off
3.8.
Users can select Over-scan when input is DTV resolution from DVI. It is only available with DVI mode.
-
CMD: 0xE4(On), 0xE5(Off)
-
It is usable only at Power on status.
-
Send to MLCD
-
NormalCommand
A.
STX
CMD
Length
Data
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommand
B.
STX
CMD
Length
Data: ID
ETX
Value
0x02
Variable
0x01
0x00
0x03
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD
-
STX
CMD
Length
Data
Check Sum
ETX
ID
Master
Value
0x02
Variable
0x02
Variable
0X01
Variable
0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
MLCD