Alentec&Orion AB,

 Grustagsvägen 4, SE-13840, Älta, Sweden, declares by the present certificate that the mentioned machinery is in 

conformity with the following standards or other normative documents (TÜV S9211282), (DIN 24558 / 10.91), 

(DIN EN 292 / 2/11.91) and has been declared in conformity with the EC Directive

 

(2006/108/EEC)

.

Alentec&Orion AB,

 

Grustagsvägen 4, SE-13840, Älta, Sverige, deklarerar genom detta certifikat att de omnämnda utrustningarna är i 

överensstämmelse med följande standarder eller normerande dokument (TÜV S9211282), (DIN 24558 / 10.91), (DIN EN 292 / 2/11.91) och 

har blivit deklarerade i enlighet med EC Direktiv 

(2006/108/EEC)

.

Alentec & Orion AB,

 

Grustagsvägen 4, SE-13840, Älta, SUÈDE, déclare par ce certificat que les pompes mentionnées sont conformes 

avec les standards suivants ou autres documents normatifs (TÜV S9211282), (DIN 24558 / 10.91), (DIN EN 292 / 2/11.91) et ont été décla

-

rés en conformité avec la Directive EC Direktiv 

(2006/108/EEC)

.

EN

SE

FR

105007

Alentec & Orion AB

 Grustagsvägen 4, SE-13840, Älta, SWEDEN · [email protected] · www.alentec.com

Krister Tynhage

Managing Director

Olle Berglund

Product Manager

SE

FR

SYMPTOM

MÖJLIG ORSAK

LÖSNING

LCD: Ingen visning

Dålig kontakt till batteriet

Kontrollera batterianslutningar

Otillräcklig noggrannhet

1. Fel K-faktor

2. Flöde är under minimum

1. Kontrollera K-faktor (kalibrering)

2. Öka flödet

Reducerat eller inget flöde

Turbinen är blockerad

Rengör turbinen

Mätaren mäter ej men flödet är tillräckligt

1. Inkorrekt installerat turbin efter rengöring

2. Eventuellt fel på kretskortet

1. Upprepa monteringen

2. Kontakta återförsäljare

SYMPTOM

CAUSE PROBABLE

SOLUTION

L’afficheur n’indique rien.

Mauvais contact des piles

Contrôler les contacts des piles.

La mesure n’est pas assez précise.

1. Le K FACTOR est incorrect.

2. Le compteur fonctionne sous le débit minimal 

acceptable.

1. Contrôler le K FACTOR, voir rubrique H.

2. Augmenter le débit pour retourner dans le 

champ des débits admissibles.

Le débit est trop faible voire nul.

TURBINE bloquée.

Nettoyer la TURBINE.

Le compteur ne compte pas mais le débit est 

régulier.

1. Mauvaise installation du compteur à turbine 

après le nettoyage.

2. La carte électronique est défectueuse.

1. Répéter la procédure de remontage.

2. Contacter votre revendeur.

Summary of Contents for 24759

Page 1: ...ER MANUAL BRUKSANVISNING MANUEL D UTILISATION 1 Alentec Orion AB Grustagsv gen 4 SE 13840 lta SWEDEN info alentec se www alentec com Part No Art Nr R f 24759 TURBINE METER TURBINM TARE COMPTEUR DIGITA...

Page 2: ...0 005 lit puls Fl de max min 5 120 l min Max arbetstryck 10 bar Spr ngtryck min 40 bar Anv ndningstemperatur 10 50 C Noggrannhet 1 efter kalibrering inom 10 90 l min spann Reproducerbarhet typ 0 3 Str...

Page 3: ...pareil n a pas t agr pour utilisa tion dans les transactions commerciales Ne pas alt rer ou modifier cet appareil Ne pas d passer la pression maximum de l quipement Voir les sp cifications techniques...

Page 4: ...piles 1 5 V de type AAA comme source d alimentation Voir la section Remplacement de la batterie Principaux composants 1 Afficheur LCD 2 Touche RESET 3 Touche ETAL 4 Bague F F NOTE Toujours prevoir la...

Page 5: ...easurement can be set Below is the legend of the symbols used to describe the actions to be performed CAL Short press on CAL key CAL CAL CAL Long press on CAL key RESET Short press on RESET key RESET...

Page 6: ...que l unit de mesure des totaux L Litres Gal Galons 8 Indique le mode D bit instantan Flow Rate 9 Indique l unit de mesure du Partiel Qts Quarts Pts Pintes L litres Gal Galons TOUCHES UTILISATEUR Le c...

Page 7: ...e CAL 2 3 Commencer la distribution ATTENTION M me si dans ce mode ni le total z rotage Reset Total ni le Total g n ral Total ne sont pas affich s ils incr mentent Il est possible de contr ler leur va...

Page 8: ...compl tement l air du circuit avant d effectuer l talonnage 2 Utiliser un r cipient chantillon sp cifique d une capacit non inf rieu re 5 litres dot d une indication gradu e bien pr cise 3 Effectuer l...

Page 9: ...ONG RESET key press The meter shows CAL and the partial at zero The Meter is ready to perform in field calibration L NGT tryck p RESET knapp M taren visar CAL och Nollst ll bart r kneverk visar noll M...