TGPS-9084GT-M12 Series User
Manual
ORing Industrial Networking Corp
150
network. On a local area network, it achieves clock accuracy in the sub-microsecond range,
making it suitable for measurement and control systems.
Label
Description
One_pps_mode
The box allows you to select One_pps_mode configurations.
The following values are possible:
Output
: enable the 1 pps clock output
Input
: enable the 1 pps clock input
Disable
: disable the 1 pps clock in/out-put
External Enable
The box allows you to configure external clock output.
The following values are possible:
True
: enable external clock output
False
: disable external clock output
VCXO_Enable
The box allows you to configure the external VCXO rate
adjustment.
The following values are possible:
True
: enable external VCXO rate adjustment
False
: disable external VCXO rate adjustment
Clock Frequency
The box allows you to set clock frequency.
The range of values is 1 - 25000000 (1 - 25MHz).
PTP Clock Configurations