TGPS-9084GT-M12 Series User
Manual
ORing Industrial Networking Corp
123
and running.
Ready
: the server is enabled, IP communications are built, and the
RADIUS module is ready to accept access attempts.
Dead
(X seconds left): access attempts are made to this server, but it
does not reply within the configured timeout. The server has
temporarily been disabled, but will be re-enabled when the dead-time
expires. The number of seconds left before this occurs is displayed in
parentheses. This state is only reachable when more than one server
is enabled.
Label
Description
#
The RADIUS server number. Click to navigate to detailed statistics of
the server
IP Address
The IP address and UDP port number (in <IP Address>:<UDP Port>
notation) of the server
Status
The current status of the server. This field has one of the following
values:
Disabled: the server is disabled.
Not Ready
: the server is enabled, but IP communication is not yet up
and running.
Ready
: the server is enabled, IP communication is up and running,
and the RADIUS module is ready to accept accounting attempts.
Dead (X seconds left)
: accounting attempts are made to this server,
but it does not reply within the configured timeout. The server has
temporarily been disabled, but will be re-enabled when the dead-time
expires. The number of seconds left before this occurs is displayed in
parentheses. This state is only reachable when more than one server
is enabled.