When using the product with the speed control mode
−23−
I/O test
Execute I/O test to check the connection status of the driver.
Input monitor
External
voltage
monitor
Output test
Top screen in the
I/O test
Each digit on the 7-segment LED display corresponds to a signal.
The LED is lit when the input signal is ON, and it is unlit when the input signal is OFF.
Use the
keys to switch the ON-OFF state of the output signal. " " is displayed when the signal is ON,
while " " is displayed when the signal is OFF.
•
•
Input monitor
IN0
IN1
IN2
IN3
IN4
IN6
IN5
IN8
IN7
•
•
Output test
OUT0
OUT1
OUT2
•
•
External voltage monitor
The voltage value input by the analog external
setter can also be checked.
JOG operation
The motor can be operated using the keys on the
OPX-2A
. The operation speed, acceleration/deceleration time
and torque will correspond to the values set in the "JOG operation speed" parameter (ID: 323), "JOG acceleration/
deceleration" parameter (ID: 324) and "JOG operation torque" parameter (ID: 2081) respectively.
The next example shows the display that appears when setting the rotation speed of the initial value to 300 r/min and
operating the motor in the reverse direction using the
key. The rotation speed is displayed while JOG operation
is executed.
Executing
Top screen in the
JOG operation
The motor rotates in the forward direction while the
key is pressed.
The motor rotates in the reverse direction while the
key is pressed.
Note
•
During operation, the motor rotates at the specified operation speed while each applicable key
is pressed. Before executing operation, consider the status of the equipment and condition of its
surroundings to confirm thoroughly that motor rotation will not cause any dangerous situation.
•
JOG operation cannot be executed while the FREE signal or STOP signal is being ON. Be sure
to execute after turning the signal OFF.