![Orientalmotor BXII Series Operating Manual Download Page 20](http://html1.mh-extra.com/html/orientalmotor/bxii-series/bxii-series_operating-manual_1651190020.webp)
When using the product with the speed control mode
−20−
5.4 Parameter mode
Parameters relating to motor operation and control can be set. These parameters are saved in the driver.
Before setting parameters, read the "
BX
Ⅱ
Series USER MANUAL" carefully to understand the basic operations,
functions and other details of the driver.
Note
•
Parameters have significant bearing on motor operation. Before setting any parameter, make
sure you fully understand the content of the parameter.
•
If operations are limited by the edit lock function, parameters cannot be edited.
•
If the value you have input is outside the setting range, "Error" will be displayed for 1 second. If
this error display appears, input a different value that falls within the setting range.
•
If a non-existent parameter ID is entered, "id-Err" will be displayed for 1 second. Check the ID
and enter the correct one.
Parameter ID
There is a unique ID in each parameter. With the
OPX-2A
, set the parameter selecting the ID.
Timing for the setting value to become effective
When a parameter is changed, the timing for the new value to become effective varies depending on the parameters,
which are the following three types.
•
Effective immediately
Executes the recalculation and setup immediately when writing the parameter.
•
Effective after stopping the operation
Executes the recalculation and setup after stopping the operation.
•
Effective after turning the power ON again
Executes the recalculation and setup after turning the power ON again.
Operation in the parameter mode
1. Use the
key to select the parameter mode.
2. Press the
key on the top screen in the parameter mode.
The display changes to the screen to select the parameter type.
3. Use the
keys to select a desired parameter ID.
4. Press the
key.
The display changes to the parameter setting screen.
Enter the parameter ID
Check the ID and setting range with the parameter list.
Parameter selection
Top screen in the
parameter mode
Use
to increase/decrease the value.
Use
to navigate through the digits.
Note
•
If the value you have input is outside the setting range, "Error" will be displayed for 1 second. If
this error display appears, input a different value that falls within the setting range.
•
If a non-existent parameter ID is entered, "id-Err" will be displayed for 1 second. Check the ID
and enter the correct one.
Initializing parameters
Parameters saved in the driver can be restored to their initial values. Execute "Initialize parameters" in the copy mode.