7 Setting
-
41
-
7.2 Pulse-input
mode
Either the 2-pulse or 1-pulse input
mode may be selected in accordance
with the controller used.
When the actuator is to be controlled
through 2-pulse signal input via the
CW pulse signal and CCW pulse
signal, set the pulse-input mode select
switch to “2P.”
When the actuator is to be controlled
through the PLS (pulse) and the DIR.
(rotating-direction), set the pulse-input
mode select switch to “1P.”
Pulse-input mode select switch
Function select switch (SW3)
Not used.
Note
•
Be sure to shut off the power before using the pulse-input mode select
switch. The new pulse input mode takes effect when the power is turned
on again.
•
The factory setting of the pulse input mode depends on the destination
country. Check the pulse input mode setting in accordance with the
pulse mode in the controller used.