6 Connection
-
36
-
•
Turning the ×10 input to “ON” will select and switch to “×10 resolution.”
•
Turning the ×10 input to “OFF” will select and switch to “×1 resolution.”
Note
Be sure to set the resolution select switch to
“×1” when “×10 input” is used. If the switch is
set to “×10,” the resolution will remain at 10
times, regardless of the “ON” or “OFF”
resolution select input.
Lever
Resolution select switch
•
ACL (Alarm clear) input
The input clears the ALARM output issued when a protective function has been
triggered. The ALARM output remains “ON” when the driver is operating normally,
then turns “OFF” when a protective function is triggered. For details, refer to
“ALARM output” on page 37 and 8 “Protective functions” on page 44.
Setting the ACL input in the ON state
clears the ALARM output. To cancel
the ALARM output, be sure to remove
the cause of the problem that has
triggered the protective function before
turning the power back on.
ACL input
(Alarm clear)
ALARM output
ON
OFF
ON
OFF
0.5 s or less
0.1 s or more
Note
•
Turning the power back on will clear the ALARM output. To cancel the
ALARM output, be sure to remove the cause of the problem that has
triggered the protective function before turning the power back on. After
the power has been shut off, wait at least 5 seconds before turning the
power back on.
•
The EEPROM data error and system error cannot be cleared using the
ACL input. Clear these errors by cycling the power. If the problem
persists, please contact the nearest office.