76 | USER MANUAL
OMX 103UNI
MENU
PROFI
6.
6.3.2a Baud rate setting of data output 1
2s
› › › OUT. ›
› › DAT. ›
› D. 1 ›
› B.D. ›
B.D.
Parameter
Display User Description
Baud rate
BD.
Setting the data output baud rate
600 Baud
0.6
1200 Baud
1.2
2400 Baud
2.4
4800 Baud
4.8
9600 Baud
9.6
DEF
19200 Baud
19.2
38400 Baud
38.4
57600 Baud
57.6
115200 Baud
115
230400 Baud
230
→
→
B.D.
6.3.2b Setting of data output 1 address
2s
› › › OUT. ›
› › DAT. ›
› D. 1 ›
› › ADR. ›
ADR.
Parameter
Display User
Setting
Description
Device address
00
0
…
31
Setting of device address on RS485 com. line
•
Range: 0…31,
DEF
00
→
→
ADR.
A.MO.
Parameter
Display User
Setting
Description
Device MODBUS
address
01
1
…
247
Setting of device address for MODBUS
•
Range: 1…247,
DEF
01
→
→
A.MO.
A.PB.
Parameter
Display User
Setting
Description
Device PROFIBUS
address
19
1
…
127
Setting of device address for PROFIBUS
•
Range: 1…127,
DEF
19
→
→
A.PB.