![Orbit Merret OMX 103UNI User Manual Download Page 51](http://html.mh-extra.com/html/orbit-merret/omx-103uni/omx-103uni_user-manual_1648179051.webp)
USER MANUAL
OMX 103UNI
| 51
6.
MENU
PROFI
6.1.3b Selecting measuring range for Input 1
2s
› INP. ›
› › › IN.1. ›
› › MO.1 ›
MO.1
MO.1
Parameter
Display User Setting
Description
Measuring range
MO.1.
Measuring ranges related to individual Types of
input listed in menu item
T.1
DC Voltmeter
DC
60m
30m
60m
U 1.
u20.
u40.
u80.
i0.1
i0.2
±30 mV
DEF
±60 mV
±1 V
±20 V
±40 V
±80 V
±90 mA
±180 mA
Process monitor
PM
I 4.
U 2.
U 5.
U10.
I 5.
I 0.
I 4.
E 4
±2 V
±5 V
±10 V
±5 mA
±20 mA
4…20 mA
DEF
4…20 mA , with error message „underflow“,
< 3,36 mA
Ohmmeter
OHM
0.1
15
30
0.1
0.3
1.5
3.0
15.0
30.0
0…15 Ω
0…30 Ω
0…150 Ω
DEF
0…300 Ω
0…1,5 kΩ
0…3 kΩ
0…15 kΩ
0…30 kΩ
Thermometer Pt xxx
Pt
Pt.1
Pt.1
Pt.2
Pt.3
Pt.4
Pt.5
Pt.6
Pt.7
Pt.A
Pt.B
Pt.C
Pt.D
Pt.E
Pt 100, 3 850 ppm/°C
-50°…130°C
DEF
Pt 100, 3 850 ppm/°C
-50°…560°C
Pt 500, 3 850 ppm/°C
-50°…560°C
Pt 1 000, 3 850 ppm/°C
-50°…130°C
Pt 1 000, 3 850 ppm/°C
-50°…560°C
Pt 100, 3 920 ppm/°C
-50°…130°C
Pt 100, 3 920 ppm/°C
-50°…457°C
Pt 50, 3 910 ppm/°C
-200°…550°C
Pt 50, 3 910 ppm/°C
-200°…1 100°C
Pt 100, 3 910 ppm/°C
-200°…130°C
Pt 100, 3 910 ppm/°C
-200°…550°C
Pt 100, 3 910 ppm/°C
-200°…1 100°C
Thermometer Ni xxx
Ni
Ni.1
Ni.1
Ni.2
Ni.3
Ni.4
Ni.5
Ni.6
Ni.7
Ni.8
Ni 1 000, 5 000 ppm/°C
-50°…100°C
DEF
Ni 1 000, 5 000 ppm/°C
-50°…250°C
Ni 1 000, 6 180 ppm/°C
-50°…80°C
Ni 1 000, 6 180 ppm/°C
-50°…250°C
Ni 10 000, 5 000 ppm/°C -50°…100°C
Ni 10 000, 5 000 ppm/°C -50°…250°C
Ni 10 000, 6 180 ppm/°C -50°…80°C
Ni 10 000, 6 180 ppm/°C -50°…250°C
→
→
Summary of Contents for OMX 103UNI
Page 13: ...USER MANUAL OMX 103UNI 13 3 DEVICE CONNECTION ...
Page 45: ...USER MANUAL OMX 103UNI 45 6 MENU PROFI ...
Page 71: ...USER MANUAL OMX 103UNI 71 6 MENU PROFI ...
Page 95: ......