Configuration according to the incoming electricity supply
To configure the equipment according to the incoming electricity supply, use the
dial on the rear of the front panel or via the mobile/web app.
This adjustment is essential for the correct operation of the load modulator.
For app or web programming to take effect, the rotating selector must be in the
“NO LIMIT.” position.
If the TMC100 transformer is not installed, the position of the dial must be in the
“NO LIMIT” position in order not to limit the load current.
Current
Single-phase
power
Three-phase
power
Current
Single-phase
power
Three-phase
power
NO LIMIT. NO LIMIT.
NO LIMIT.
28 A
6,44 kW
19,32 kW
10 A
2,3 kW
6,928 kW
30 A
6,9 kW
20,785 kW
13 A
3 kW
9 kW
35 A
8,05 kW
24,249 kW
15 A
3,45 kW
10,392 kW
40 A
9,2 kW
27,713 kW
18 A
4,14 kW
12,42 kW
45 A
10,35 kW
31,177 kW
20 A
4,6 kW
13,856 kW
50 A
11,5 kW
34,641 kW
23 A
5,3 kW
15,9 kW
55 A
12,65 kW
37,95 kW
25 A
5,75 kW
17,321 kW
63 A
14,49 kW
43,648 kW