Untrusted Interfaces
Ethernet ports may be configured as untrusted interfaces. Untrusted interfaces connect to
untrusted zones that the administrator does not want to place within the normal switched or
routed enterprise network because of security or convenience. Non-Conduit traffic from the
WAN to an untrusted interface is unable to communicate to any network point inside of the
Talari WAN. For example, a user on the enterprise LAN cannot ping, or otherwise
communicate with, any entity on the Ethernet domain attached to an untrusted interface
through the Talari Appliance or vice-versa. An untrusted segment is entirely isolated from the
rest of the network with the exception of the Talari WAN’s own AES encrypted paths.
Hardware Specifications
The T5200 has the following hardware specifications:
Specification
Power
100-240 volts
50-60 Hz, 9-3.5 Amp
Redundant 740W ATX AC power supply
UL approved, FCC compliant
Physical Dimensions
EIA RS-310 standards 2U
437mm (W) x 648mm (D) x 89mm (H) (17.2” x 25.5” x 3.5”)
Mounting Options
Rack mount
Universal 2U rail kit (included)
Link LEDs
Link activity
Link speed
LCD
Six button LCD
Operating Temperature
0 to 40° C (32 to 104° F)
Storage Temperature
-20 to 80° C (-4 to 176° F)
Relative Humidity
10% to 90% non-condensing
Network Interfaces
4 multi-mode fiber 10 Gigabit Ethernet ports (SFP+) with bypass
4 copper Gigabit Ethernet ports with bypass
2 copper Gigabit Ethernet ports on motherboard (one limited
to full duplex)
100 Mbps
Other Interfaces
1 VGA port
4 USB 2.0 ports
1 DB9 console port
Mean Time Between Failure
(MTBF)
31,816 hours
Table 2: Hardware Specifications