Oracle Talari T5200 | Hardware Guide
Adding Your T5200 to the Rack
1.
Extend the outer rails as illustrated in
Figure 13
.
2.
Align the inner rails attached to the chassis with the outer rails attached to the rack.
3.
Slide the inner rails into the outer rails, keep the pressure even on both sides, and
push the chassis into the rack. When the chassis is pushed completely into the rack, it
should click into the locked position.
4.
Optional: Use the screws included in the mounting kit to secure the front of the chassis
to the rack.
Figure 13: Slide Appliance Chassis into Rack Using Installed Rails
LAN/WAN Connections
When connecting each Ethernet (LAN or WAN) cable to the appropriate connector on the
T5200:
Position the cables carefully so that they do not put strain on the connectors.
Organize cables in bundles so that cables do not intertwine.
Inspect the cables to make sure that the routing and bend radii are
satisfactory. Reposition cables if necessary.
Install cable ties in accordance with site requirements.