DIMM names in appliance logs and the Maintenance > Hardware view are displayed with the
full name, such as /SYS/MB/P0/D7.
Fan Modules
The Fan Modules and Fan Module LEDs of the storage controller are shown in the following
figure. The following LEDs are lit when a fan module fault is detected:
■
Front and rear Service Action Required LEDs
■
Fan Module Service Action Required (TOP) LED on the front of the server
■
Fan Fault LED on or adjacent to the faulty fan module
The system Overtemp LED might light if a fan fault causes an increase in system operating
temperature.