Electrostatic Discharge Precautions
■
Remove all plastic, vinyl, and foam material from the work area.
■
Wear an antistatic wrist strap at all times when handling any CRU.
■
Before handling any CRU, discharge any static electricity by touching a grounded surface.
■
Do not remove a CRU from its antistatic protective bag until you are ready to install it.
■
After removing a CRU from the chassis, immediately place it in an antistatic bag or
antistatic packaging.
■
Handle any card that is part of a CRU by its edges only and avoid touching the components
or circuitry.
■
Do not slide a CRU over any surface.
■
Limit body movement (which builds up static electricity) during the removal and
replacement of a CRU.
Tasks
Shelf Tasks
▼
Replacing a Drive
The shelf drives are hot-swappable and may be replaced without removing power from the
shelf. The replacement drive must be of the same capacity and type as the drive to be replaced.
To avoid possible data loss when removing non-faulted drives, label each drive with the number
of the slot from which it was removed and reinstall each drive into the same slot.
Faulted drives are indicated by an amber LED. Go to the Maintenance > Hardware section of
the BUI and double click the shelf thumbnail to view Details for HDDs or
to turn on the
locator LED.
Locate the failed disk drive at the front of the chassis.